Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2768▼ 554 respecto a la semana anterior
Críticas / altas1325▼ 178 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)268▼ 242 respecto a la semana anterior
26.291 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Analizada | Alta (7.1) | 0.38% | — | Tp-link Tapo C100 FirmwareTp-link Tapo C101 Firmware | 19/8/2026 | 4/9/2026 | Tapo C100/C101 V5 contains a null pointer dereference vulnerability in the RTSP service. An attacker on the local network can send specially crafted requests that cause the service to dereference an invalid pointer, resulting in a service crash and device reboot. Successful exploitation can disrupt live video… | |
| Analizada | Media (6.7) | 0.16% | — | IBM Power System S1122 (9824-22a) FirmwareIBM Power System S1124 (9824-42a) FirmwareIBM Power System S1122s (9824-22b) FirmwareIBM Power System S1114 (9824-41b) Firmware+15 | 19/8/2026 | 25/8/2026 | Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the host firmware. An attacker with service access to the service processor can supply a carefully crafted command that could leak the contents of hardware registers that should be… | |
| Analizada | Alta (8.3) | 0.15% | — | IBM Power System E1080 (9080-hex) FirmwareIBM Power System E1180 (9080-heu) FirmwareIBM Power System S922 (9009-22g) FirmwareIBM Power System H922 (9223-22s) Firmware+5 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform… | |
| Analizada | Media (6.8) | 0.34% | — | IBM Power System S922 (9009-22g) FirmwareIBM Power System H922 (9223-22s) FirmwareIBM Power System S914 (9009-41g) FirmwareIBM Power System S924 (9009-42g) Firmware+5 | 19/8/2026 | 25/8/2026 | IBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP firmware update process. An attacker with authenticated administrator-level access to the FSP can, under specific conditions, execute arbitrary code,… | |
| Analizada | Alta (8.2) | 0.17% | — | IBM Power System S1122 (9824-22a) FirmwareIBM Power System S1124 (9824-42a) FirmwareIBM Power System S1122s (9824-22b) FirmwareIBM Power System S1114 (9824-41b) Firmware+6 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, and FW1110.00 through FW1110.30 is affected by a vulnerability in the interface between the BMC and the host system. An attacker with service access to the BMC can send a specially crafted command, allowing arbitrary code to be executed on the host system, giving full control over… | |
| Analizada | Alta (8.1) | 0.15% | — | IBM Power System S1122 (9824-22a) FirmwareIBM Power System S1124 (9824-42a) FirmwareIBM Power System S1122s (9824-22b) FirmwareIBM Power System S1114 (9824-41b) Firmware+25 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or… | |
| Analizada | Alta (8.2) | 0.17% | — | IBM Power System S1122 (9824-22a) FirmwareIBM Power System S1124 (9824-42a) FirmwareIBM Power System S1122s (9824-22b) FirmwareIBM Power System S1114 (9824-41b) Firmware+25 | 19/8/2026 | 25/8/2026 | Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1, and OP940.00 - OP940.81 is affected by a vulnerability in the service processor mailbox interface. An attacker with authenticated service-level access to the BMC/FSP can… | |
| Analizada | Alta (8.2) | 0.17% | — | IBM Power System S1122 (9824-22a) FirmwareIBM Power System S1124 (9824-42a) FirmwareIBM Power System S1122s (9824-22b) FirmwareIBM Power System S1114 (9824-41b) Firmware+25 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in host firmware configuration parsing. An attacker with service-level access to the BMC/FSP… | |
| Analizada | Media (6.9) | 0.22% | — | IBM Power System E1080 (9080-hex) FirmwareIBM Power System E1180 (9080-heu) FirmwareIBM Power System S922 (9009-22g) FirmwareIBM Power System H922 (9223-22s) Firmware+5 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the… | |
| Analizada | Alta (8.2) | 0.17% | — | IBM Power System E1180 (9080-heu) FirmwareIBM Power System S1122 (9824-22a) FirmwareIBM Power System S1124 (9824-42a) FirmwareIBM Power System S1122s (9824-22b) Firmware+15 | 19/8/2026 | 24/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can execute arbitrary code on the host system, giving full control… | |
| Analizada | Crítica (9.6) | 0.36% | — | IBM Power System E1080 (9080-hex) FirmwareIBM Power System E1180 (9080-heu) FirmwareIBM Power System S922 (9009-22g) FirmwareIBM Power System H922 (9223-22s) Firmware+5 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation… | |
| Analizada | Alta (8.4) | 0.32% | — | IBM Power System E1080 (9080-hex) FirmwareIBM Power System E1180 (9080-heu) FirmwareIBM Power System S922 (9009-22g) FirmwareIBM Power System H922 (9223-22s) Firmware+5 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full… | |
| Analizada | Alta (7.6) | 0.28% | — | IBM Power System E1080 (9080-hex) FirmwareIBM Power System E1180 (9080-heu) FirmwareIBM Power System S922 (9009-22g) FirmwareIBM Power System H922 (9223-22s) Firmware+5 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and… | |
| Analizada | Crítica (9.6) | 0.35% | — | IBM Power System E1180 (9080-heu) FirmwareIBM Power System E1080 (9080-hex) FirmwareIBM Power System S922 (9009-22g) FirmwareIBM Power System H922 (9223-22s) Firmware+5 | 19/8/2026 | 25/8/2026 | IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the… | |
| Analizada | Alta (8.2) | 0.17% | — | IBM Power System S1122 (9824-22a) FirmwareIBM Power System S1124 (9824-42a) FirmwareIBM Power System S1122s (9824-22b) FirmwareIBM Power System S1114 (9824-41b) Firmware+15 | 19/8/2026 | 26/8/2026 | Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the host firmware boot process image validation path. An attacker with service access to the service processor can supply a maliciously crafted code update image, allowing arbitrary code to… | |
| En análisis | Media (6) | 0.10% | — | IBM Power System S1122 (9824-22a) FirmwareIBM Power System S1124 (9824-42a) FirmwareIBM Power System S1122s (9824-22b) FirmwareIBM Power System S1114 (9824-41b) Firmware+15 | 19/8/2026 | 25/8/2026 | IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 IBM PowerVM could allow a local attacker to obtain sensitive information or cause a denial of service due to improper control of format strings. | |
| Analizada | Alta (7.1) | 0.24% | — | Tp-link Tapo C200 Firmware | 18/8/2026 | 4/9/2026 | An improper input validation vulnerability in the configuration service for processing encrypted credential data has been identified in Tapo C200 v5. An attacker can send oversized crypted ciphertext values that may trigger exception handling failures, due to insufficient validation, causing the affected device to… | |
| Analizada | Alta (8.7) | 0.30% | 💥 PoC | Tp-link Tapo C120 FirmwareTp-link Tapo C200 Firmware | 18/8/2026 | 4/9/2026 | Tapo C120 v1 and C200 v5 contain an improper authentication vulnerability within the login authentication verification module. An attacker on the local network can exploit weaknesses in challenge parameter validation to bypass normal authentication controls and obtain administrative session tokens. Successful… | |
| Analizada | Media (5.3) | 0.12% | — | Tp-link Tl-wr820n Firmware | 12/8/2026 | 9/9/2026 | The web interface of the affected device relies on the HTTP referrer header as part of request validation. Requests containing empty Referer value, or omitting the Referer header entirely, may be accepted and processed due to insufficient validation logic. Successful exploitation may allow an adjacent attacker with… | |
| Analizada | Media (4) | 0.10% | — | Intel Xeon Bronze 3408u FirmwareIntel Xeon Gold 5403n FirmwareIntel Xeon Gold 5411n FirmwareIntel Xeon Gold 5412u Firmware+137 | 11/8/2026 | 28/8/2026 | Improper input validation for some Intel(R) Xeon(R) processors within firmware may allow an escalation of privilege. Startup code and smm adversary with a privileged user combined with a high complexity attack may enable data alteration. This result may potentially occur via local access when attack requirements are… | |
| Pendiente de análisis | Media (4) | 0.12% | — | Intel Uefi FirmwareAI | 11/8/2026 | 12/8/2026 | Incomplete cleanup in some UEFI firmware for some Intel(R) reference platforms within UEFI may allow an information disclosure. System software adversary with a privileged user combined with a low complexity attack may enable data exposure. This result may potentially occur via local access when attack requirements… | |
| Analizada | Alta (8.5) | 0.12% | — | Intel Xeon 6315p FirmwareIntel Xeon 6325p FirmwareIntel Xeon 6333p FirmwareIntel Xeon 6337p Firmware+171 | 11/8/2026 | 31/8/2026 | Improper access control in the firmware for some in Alias Checking Trusted Module for some Intel(R) Xeon(R) processors may allow an escalation of privilege. Startup code and SMM adversary with a privileged user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur… | |
| Analizada | Alta (7.2) | 0.09% | — | Intel Xeon 634 FirmwareIntel Xeon 636 FirmwareIntel Xeon 638 FirmwareIntel Xeon 654 Firmware+86 | 11/8/2026 | 31/8/2026 | Improper access control for some Intel(R) Processors within Ring 3: User Applications may allow an escalation of privilege. Simple hardware adversary with an authenticated user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack… | |
| Analizada | Media (4.3) | 0.23% | — | Netgear R7000 Firmware | 11/8/2026 | 9/9/2026 | Insufficient input validation vulnerability in the NETGEAR R7000 models allows authenticated administrators connected to the local network to make unauthorized modification to router software and functionality. | |
| Analizada | Media (4.9) | 0.91% | — | Netgear Be9300 FirmwareNetgear Mr60 FirmwareNetgear Ms60 FirmwareNetgear R6700ax Firmware+22 | 11/8/2026 | 9/9/2026 | A command injection vulnerability in the listed NETGEAR models allows a network-adjacent attacker with the ability to intercept and modify local network traffic (attacker-in-the-middle) to compromise the confidentiality and integrity of the affected device. This issue is limited to certain region-specific SKUs. |