| Analizada | Media (6.5) | 0.91% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+13 | 15/5/2023 | 17/6/2026 | Multiple CODESYS products in multiple versions are prone to a improper input validation vulnerability. An authenticated remote attacker may craft specific requests that use the vulnerability leading to a denial-of-service condition. | |
| Modificada | Media (4.3) | 0.73% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+10 | 15/5/2023 | 17/6/2026 | Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type. | |
| Modificada | Crítica (9.8) | 82% | 💥 Exploit | Wago Compact Controller 100 FirmwareWago Edge Controller FirmwareWago Pfc100 FirmwareWago Pfc200 Firmware+3 | 15/5/2023 | 17/6/2026 | In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise. | |
| Modificada | Alta (8.8) | 0.88% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+12 | 23/3/2023 | 17/6/2026 | In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device. | |
| Modificada | Alta (8.8) | 1.0% | — | Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Pfc100+11 | 23/3/2023 | 17/6/2026 | The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device. | |
| Modificada | Crítica (9.8) | 1.1% | — | Wago 751-9301 FirmwareWago 752-8303/8000-002 FirmwareWago Pfc100 FirmwareWago Pfc200 Firmware+3 | 27/2/2023 | 17/6/2026 | The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise. | |
| Modificada | Media (5.3) | 0.25% | — | Wago 751-9301 FirmwareWago 752-8303/8000-002 FirmwareWago Pfc100 FirmwareWago Pfc200 Firmware+3 | 27/2/2023 | 17/6/2026 | A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the… | |
| Modificada | Crítica (9.8) | 0.74% | — | Wago 751-9301 FirmwareWago 752-8303/8000-002 FirmwareWago Pfc100 FirmwareWago Pfc200 Firmware+3 | 27/2/2023 | 17/6/2026 | The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device. | |
| Modificada | Media (6.1) | 0.38% | — | Wago 751-9301 FirmwareWago 752-8303/8000-002 FirmwareWago Pfc100 FirmwareWago Pfc200 Firmware+3 | 27/2/2023 | 17/6/2026 | The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability. | |
| Modificada | Media (5.9) | 0.63% | — | Wago Pfc100 FirmwareWago Pfc200 FirmwareWago Touch Panel 600 Advanced FirmwareWago Touch Panel 600 Standard Firmware+3 | 19/1/2023 | 17/6/2026 | The vulnerability allows a remote unauthenticated attacker to download a backup file, if one exists. That backup file might contain sensitive information like credentials and cryptographic material. A valid user has to create a backup after the last reboot for this attack to be successfull. | |
| Analizada | Alta (7.8) | 0.17% | — | Pilz PMCCodesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000+60 | 26/12/2022 | 17/6/2026 | In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device. | |
| Modificada | Media (6.5) | 0.63% | — | Siemens Pxc00-e96.a FirmwareSiemens Pxc100-e96.a FirmwareSiemens Pxx-485.3 FirmwareSiemens Pxc16.2-pe.a Firmware+5 | 13/12/2022 | 17/6/2026 | A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON… | |
| Modificada | Alta (8.7) | 1.4% | — | Siemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Source CodeSiemens Apogee Modular Building Controller Firmware+17 | 11/10/2022 | 17/6/2026 | A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions <… | |
| Modificada | Alta (7.8) | 0.38% | — | Acer Altos T110 F3 FirmwareAcer Ap130 F2 FirmwareAcer Aspire 1600x FirmwareAcer Aspire 1602m Firmware+30 | 23/9/2022 | 9/7/2026 | There is a stack buffer overflow vulnerability, which could lead to arbitrary code execution in UEFI DXE driver on some Acer products. An attack could exploit this vulnerability to escalate privilege from ring 3 to ring 0, and hijack control flow during UEFI DXE execution. This affects Altos T110 F3 firmware version… | |
| Modificada | Alta (7.5) | 0.89% | — | Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+15 | 11/7/2022 | 17/6/2026 | In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected. | |
| Modificada | Alta (7.5) | 0.89% | — | Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+15 | 11/7/2022 | 17/6/2026 | In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected. | |
| Modificada | Alta (7.5) | 1.5% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+14 | 7/4/2022 | 17/6/2026 | A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system. | |
| Modificada | Media (6.5) | 0.61% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+6 | 7/4/2022 | 17/6/2026 | A bug in CmpUserMgr component can lead to only partially applied security policies. This can result in enabled, anonymous access to components part of the applied security policy. | |
| Modificada | Alta (7.5) | 1.3% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+16 | 7/4/2022 | 17/6/2026 | An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed. | |
| Modificada | Alta (8.1) | 1.1% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+14 | 7/4/2022 | 17/6/2026 | A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products. | |
| Modificada | Alta (7.1) | 0.89% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+16 | 7/4/2022 | 17/6/2026 | An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed,… | |
| Modificada | Media (6.5) | 1.0% | — | Codesys Control FOR Beaglebone SLCodesys Control FOR Beckhoff Cx9020Codesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SL+16 | 7/4/2022 | 17/6/2026 | An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. | |
| Modificada | Alta (8.8) | 2.4% | — | Siemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Source CodeSiemens Apogee Modular Building Controller Firmware+18 | 9/11/2021 | 17/6/2026 | A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions <… | |
| Modificada | Alta (8.8) | 2.4% | — | Siemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Source CodeSiemens Apogee Modular Building Controller Firmware+18 | 9/11/2021 | 17/6/2026 | A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions <… | |
| Modificada | Crítica (9.8) | 3.0% | — | Siemens Nucleus NETSiemens Nucleus Readystart V3Siemens Nucleus Source CodeSiemens Apogee Modular Building Controller Firmware+18 | 9/11/2021 | 17/6/2026 | A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions <… |