| Modificada | Media (6.1) | 0.51% | — | Crealogix Ebics Server | 10/10/2022 | 17/6/2026 | A vulnerability was found in Crealogix EBICS 7.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /ebics-server/ebics.aspx. The manipulation leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be… | |
| Modificada | Alta (8.6) | 2.3% | — | Rockwellautomation Armor Compact Guardlogix 5370 FirmwareRockwellautomation Compact Guardlogix 5370 FirmwareRockwellautomation Compactlogix 5370 L1 FirmwareRockwellautomation Compactlogix 5370 L2 Firmware+5 | 27/7/2022 | 17/6/2026 | The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which… | |
| Modificada | Media (6.5) | 1.7% | — | Rockwellautomation Micrologix 1100 FirmwareRockwellautomation Micrologix 1400 Firmware | 20/7/2022 | 17/6/2026 | The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks. | |
| Modificada | Alta (8.6) | 2.1% | — | Rockwellautomation Compactlogix 5380 FirmwareRockwellautomation Compact Guardlogix 5380 FirmwareRockwellautomation Compactlogix 5480 FirmwareRockwellautomation Controllogix 5580 Firmware+5 | 2/6/2022 | 17/6/2026 | A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project… | |
| Modificada | Crítica (9.8) | 5.2% | — | Rockwellautomation Compactlogix 1768-l43 FirmwareRockwellautomation Compactlogix 1768-l45 FirmwareRockwellautomation Compactlogix 1769-l31 FirmwareRockwellautomation Compactlogix 1769-l32c Firmware+20 | 11/4/2022 | 17/6/2026 | An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the… | |
| Modificada | Alta (7.2) | 3.5% | — | Rockwellautomation Controllogix 5580 FirmwareRockwellautomation Guardlogix 5580 FirmwareRockwellautomation Compactlogix 5380 FirmwareRockwellautomation Compactlogix 5480 Firmware+1 | 1/4/2022 | 17/6/2026 | Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user. | |
| Modificada | Media (5.5) | 0.81% | — | Microsoft Fslogix | 10/11/2021 | 19/8/2026 | FSLogix Information Disclosure Vulnerability | |
| Modificada | Alta (8.6) | 2.6% | — | Rockwellautomation Micrologix 1100 Firmware | 9/7/2021 | 17/6/2026 | Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller… | |
| Modificada | Alta (7.5) | 3.0% | — | Rockwellautomation Micro800 FirmwareRockwellautomation Micrologix 1400 Firmware | 3/6/2021 | 17/6/2026 | When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller (Micro800: All versions,… | |
| Modificada | Alta (8.6) | 1.7% | — | Rockwellautomation Micrologix 1400 Firmware | 25/3/2021 | 17/6/2026 | Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a denial-of-service… | |
| Analizada | Crítica (9.8) | 64% | ⚠ Explotación activa | Rockwellautomation Factorytalk Services PlatformRockwellautomation Rslogix 5000Rockwellautomation Studio 5000 Logix Designer | 3/3/2021 | 17/6/2026 | Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact… | |
| Modificada | Alta (7.5) | 5.6% | — | Rockwellautomation Micrologix 1100 B Firmware | 3/12/2020 | 17/6/2026 | An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000 and Series B FRN… | |
| Modificada | Baja (3.3) | 1.5% | — | Rockwellautomation Studio 5000 Logix Designer | 14/7/2020 | 17/6/2026 | Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program. | |
| Modificada | Alta (8.2) | 1.3% | — | Rockwellautomation EDS SubsystemRockwellautomation RslinxRockwellautomation Rslinx EnterpriseRockwellautomation Rsnetworx+1 | 20/5/2020 | 17/6/2026 | Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is… | |
| Modificada | Media (5.5) | 2.6% | — | Rockwellautomation EDS SubsystemRockwellautomation RslinxRockwellautomation Rslinx EnterpriseRockwellautomation Rsnetworx+1 | 19/5/2020 | 17/6/2026 | Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.… | |
| Modificada | Crítica (9.8) | 4.4% | — | Rockwellautomation Micrologix 1400 A FirmwareRockwellautomation Micrologix 1400 B FirmwareRockwellautomation Micrologix 1100 FirmwareRockwellautomation Rslogix 500 | 16/3/2020 | 17/6/2026 | Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could… | |
| Modificada | Alta (7.5) | 4.0% | — | Rockwellautomation Micrologix 1400 A FirmwareRockwellautomation Micrologix 1400 B FirmwareRockwellautomation Micrologix 1100 FirmwareRockwellautomation Rslogix 500 | 16/3/2020 | 17/6/2026 | Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller… | |
| Modificada | Alta (7.5) | 2.8% | — | Rockwellautomation Micrologix 1400 A FirmwareRockwellautomation Micrologix 1400 B FirmwareRockwellautomation Micrologix 1100 FirmwareRockwellautomation Rslogix 500 | 16/3/2020 | 17/6/2026 | Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable. | |
| Modificada | Baja (3.3) | 0.41% | — | Rockwellautomation Micrologix 1400 A FirmwareRockwellautomation Micrologix 1400 B FirmwareRockwellautomation Micrologix 1100 FirmwareRockwellautomation Rslogix 500 | 16/3/2020 | 17/6/2026 | Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be… | |
| Modificada | Crítica (9.8) | 10.0% | — | Rockwellautomation Compactlogix 5370 L1 FirmwareRockwellautomation Compactlogix 5370 L2 FirmwareRockwellautomation Compactlogix 5370 L3 FirmwareRockwellautomation Armor Compact Guardlogix 5370 Firmware | 1/5/2019 | 17/6/2026 | An attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor… | |
| Modificada | Alta (7.5) | 6.1% | — | Rockwellautomation Compactlogix 5370 L1 FirmwareRockwellautomation Compactlogix 5370 L2 FirmwareRockwellautomation Compactlogix 5370 L3 FirmwareRockwellautomation Compact Guardlogix 5370 Firmware+1 | 1/5/2019 | 17/6/2026 | An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier. | |
| Modificada | Media (6.1) | 3.1% | — | Rockwellautomation Micrologix 1400 A FirmwareRockwellautomation Micrologix 1400 B FirmwareRockwellautomation Micrologix 1100 FirmwareRockwellautomation Compactlogix 5370 L1 Firmware+2 | 25/4/2019 | 17/6/2026 | In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix… | |
| Modificada | Crítica (9.8) | 5.7% | — | Rockwellautomation RslogixRockwellautomation Plc5 1785-lx FirmwareRockwellautomation Slc5/01 1747-l5x Firmware | 26/3/2019 | 16/6/2026 | The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s… | |
| Modificada | Alta (8.6) | 4.3% | — | Rockwellautomation Micrologix 1400 FirmwareRockwellautomation 1756-enbt FirmwareRockwellautomation 1756-eweb Series A FirmwareRockwellautomation 1756-eweb Series B Firmware+12 | 7/12/2018 | 17/6/2026 | Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set… | |
| Modificada | Crítica (9.8) | 3.4% | — | Smartlogix Wp-insert | 28/9/2018 | 17/6/2026 | The Wp-Insert plugin through 2.4.2 for WordPress allows upload of arbitrary PHP code because of the exposure and configuration of FCKeditor under fckeditor/editor/filemanager/browser/default/browser.html, fckeditor/editor/filemanager/connectors/test.html, and fckeditor/editor/filemanager/connectors/uploadtest.html. |