Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2855▼ 333 respecto a la semana anterior
Críticas / altas1381▼ 36 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)296▼ 213 respecto a la semana anterior
–

62 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaCrítica (9.8)2.5%—Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Linux+1026/3/202017/6/2026
CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.
ModificadaMedia (6.5)1.9%—Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Linux+1124/1/202017/6/2026
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.
ModificadaCrítica (9.8)1.9%—Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Linux+1020/11/201917/6/2026
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.
ModificadaMedia (6.5)1.4%—Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Pfc100+617/9/201917/6/2026
3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition.
ModificadaAlta (7.5)1.7%—Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Pfc100+1017/9/201917/6/2026
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.
ModificadaAlta (8.8)1.9%—Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Pfc100+617/9/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.
ModificadaCrítica (9.8)5.8%—Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Linux+913/9/201917/6/2026
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.
ModificadaAlta (7.5)3.2%—Codesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000Codesys Control FOR Linux+913/9/201917/6/2026
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.
ModificadaAlta (8.8)0.28%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+815/8/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless…
ModificadaAlta (7.5)3.0%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1419/2/201917/6/2026
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
ModificadaAlta (7.5)2.6%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1119/2/201917/6/2026
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.
ModificadaCrítica (9.8)1.3%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+829/1/201917/6/2026
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.