CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaMedia (6.5)1.7%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+814/5/201917/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime…
ModificadaCrítica (9.1)2.7%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+814/5/201917/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime…
ModificadaAlta (8.8)1.9%—Siemens Simatic PCS 7Siemens Simatic WinccSiemens Simatic Wincc (tia Portal)Siemens Simatic Wincc Runtime Professional14/5/201917/6/2026
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA…
ModificadaMedia (5.5)0.27%—Siemens Simatic PCS 7Siemens Simatic WinccSiemens Simatic Wincc (tia Portal)Siemens Simatic Wincc Runtime Professional14/5/201917/6/2026
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA…
ModificadaAlta (8.8)1.5%—Siemens Simatic PCS 7Siemens Simatic WinccSiemens Simatic Wincc (tia Portal)Siemens Simatic Wincc Runtime Professional14/5/201917/6/2026
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA…
ModificadaAlta (7.5)1.6%—Siemens Simatic Cp443-1 OPC UA FirmwareSiemens Simatic ET 200 Open Controller CPU 1515sp PC2 FirmwareSiemens Simatic IPC Diagmonitor FirmwareSiemens Simatic NET PC Software Firmware+2317/4/201917/6/2026
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl.…
ModificadaAlta (7.5)1.4%—Siemens Cp1604 FirmwareSiemens Cp1616 FirmwareSiemens Simatic Rf185c FirmwareSiemens Simatic Cp343-1 Advanced Firmware+4917/4/201917/6/2026
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the…
ModificadaAlta (8.8)1.7%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+813/12/201817/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14),…
ModificadaAlta (8.1)1.7%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+813/12/201817/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced…
ModificadaAlta (7.5)3.6%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+813/12/201817/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced…
ModificadaAlta (7.5)2.4%—Siemens Openpcs 7Siemens Simatic BatchSiemens Simatic NET PCSiemens Simatic PCS 7+524/4/201817/6/2026
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0…
ModificadaMedia (4.9)1.9%—Siemens Simatic WinccSiemens Simatic Wincc (tia Portal)Siemens Simatic Wincc Runtime11/5/201717/6/2026
A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the…
ModificadaMedia (6.4)0.38%—Siemens Primary Setup ToolSiemens Security Configuration ToolSiemens Simatic IT Production SuiteSiemens Simatic NET PC Software+1415/11/201617/6/2026
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7…
ModificadaAlta (9.3)7.1%—Siemens Simatic Wincc Flexible RuntimeSiemens Simatic Wincc Runtime16/9/201116/6/2026
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.