Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2704▼ 598 respecto a la semana anterior
Críticas / altas1288▼ 199 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)299▼ 211 respecto a la semana anterior
–

31 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.1)0.91%—Siemens Simatic CP 343-1 STD FirmwareSiemens Simatic CP 343-1 Lean FirmwareSiemens Simatic CP 343-1 ADV FirmwareSiemens Simatic CP 443-1 STD Firmware+7511/5/201717/6/2026
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
ModificadaAlta (7.1)1.1%—Siemens Simatic CP 343-1 STD FirmwareSiemens Simatic CP 343-1 Lean FirmwareSiemens Simatic CP 343-1 ADV FirmwareSiemens Simatic CP 443-1 STD Firmware+8911/5/201717/6/2026
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
ModificadaAlta (7.8)2.4%—Siemens Simatic S7-1200 FirmwareSiemens Simatic S7-1200 CPU 1211c FirmwareSiemens Simatic S7-1200 CPU 1212c FirmwareSiemens Simatic S7-1200 CPU 1212fc Firmware+522/4/201316/6/2026
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
ModificadaAlta (7.8)2.4%—Siemens Simatic S7-1200 FirmwareSiemens Simatic S7-1200 CPU 1211c FirmwareSiemens Simatic S7-1200 CPU 1212c FirmwareSiemens Simatic S7-1200 CPU 1212fc Firmware+522/4/201316/6/2026
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
ModificadaMedia (4.3)2.6%—Siemens Simatic S7-1200 FirmwareSiemens Simatic S7-1200 CPU 1211c FirmwareSiemens Simatic S7-1200 CPU 1212c FirmwareSiemens Simatic S7-1200 CPU 1212fc Firmware+510/10/201216/6/2026
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
ModificadaMedia (4.3)1.5%—Siemens Simatic S7-1200 FirmwareSiemens Simatic S7-1200 CPU 1211c FirmwareSiemens Simatic S7-1200 CPU 1212c FirmwareSiemens Simatic S7-1200 CPU 1212fc Firmware+525/9/201216/6/2026
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.