Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2614▼ 473 respecto a la semana anterior
Críticas / altas1270▼ 74 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)243▼ 274 respecto a la semana anterior
–

46 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (8.8)1.2%—Codesys PlcwinntCodesys Runtime Toolkit24/6/202217/6/2026
In multiple CODESYS products, a remote attacker may craft a request which may cause an unexpected sign extension, resulting in a denial-of-service condition or memory overwrite.
ModificadaAlta (8.8)1.4%—Codesys PlcwinntCodesys Runtime Toolkit24/6/202217/6/2026
In multiple CODESYS products, a low privileged remote attacker may craft a request, which may cause a heap-based buffer overflow, resulting in a denial-of-service condition or memory overwrite. User interaction is not required.
ModificadaMedia (6.5)1.0%—Codesys PlcwinntCodesys Runtime Toolkit24/6/202217/6/2026
In multiple CODESYS products, a low privileged remote attacker may craft a request that cause a read access to an uninitialized pointer, resulting in a denial-of-service. User interaction is not required.
ModificadaCrítica (9.8)1.2%—Codesys PlcwinntCodesys Runtime Toolkit24/6/202217/6/2026
In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller.
ModificadaAlta (7.5)1.0%—Codesys Development SystemCodesys Edge GatewayCodesys GatewayCodesys HMI SL+624/6/202217/6/2026
In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.
ModificadaAlta (8.1)1.1%—Codesys PlcwinntCodesys Runtime Toolkit24/6/202217/6/2026
Multiple products of CODESYS implement a improper error handling. A low privilege remote attacker may craft a request, which is not properly processed by the error handling. In consequence, the file referenced by the request could be deleted. User interaction is not required.
AnalizadaMedia (6.5)0.85%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2626/10/202117/6/2026
A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition.
AnalizadaAlta (8.1)0.88%—Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+2626/10/202117/6/2026
A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite.
AnalizadaAlta (7.5)2.7%—Wago 750-8202 FirmwareWago 750-8203 FirmwareWago 750-8204 FirmwareWago 750-8206 Firmware+1126/10/202117/6/2026
In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.
ModificadaAlta (7.5)0.96%—Codesys Runtime Toolkit3/8/202117/6/2026
All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions.
AnalizadaAlta (7.5)7.2%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2525/5/202117/6/2026
CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.
AnalizadaAlta (7.5)7.4%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2525/5/202117/6/2026
CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow.
AnalizadaMedia (5.3)0.27%—Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+2425/5/202117/6/2026
CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command.
ModificadaMedia (6.5)1.2%—Codesys PlcwinntCodesys Runtime ToolkitCodesys SP Realtime NT20/12/201917/6/2026
3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference.
ModificadaAlta (7.5)1.8%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+615/8/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the…
ModificadaCrítica (9.8)1.9%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+615/8/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or…
ModificadaAlta (8.8)0.28%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+815/8/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless…
ModificadaAlta (7.5)3.0%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1419/2/201917/6/2026
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
ModificadaAlta (7.5)2.6%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1119/2/201917/6/2026
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.
ModificadaCrítica (9.8)1.3%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+829/1/201917/6/2026
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.
ModificadaMedia (5)3.6%—3s-software Codesys Runtime Toolkit31/1/201417/6/2026
Smart Software Solutions (3S) CoDeSys Runtime Toolkit before 2.4.7.44 allows remote attackers to cause a denial of service (NULL pointer dereference and application crash) via unspecified vectors.