Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas3020▼ 63 respecto a la semana anterior
Críticas / altas1413▲ 57 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)382▼ 128 respecto a la semana anterior
–

57 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.8)1.4%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition.
ModificadaAlta (7.8)0.66%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is…
ModificadaAlta (7.8)1.2%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
ModificadaAlta (7.8)1.2%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file is imported to IGSS Definition.
ModificadaAlta (7.8)1.2%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
ModificadaAlta (7.8)1.3%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
ModificadaAlta (7.8)1.3%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition.
ModificadaAlta (7.8)1.3%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied data, when a malicious CGF file is imported to IGSS Definition.
ModificadaAlta (7.8)1.2%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition.
ModificadaAlta (7.8)1.2%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is being parsed by IGSS Definition.
ModificadaAlta (7.8)1.2%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.
ModificadaAlta (7.8)0.85%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)1.2%—Schneider-electric Interactive Graphical Scada System11/6/202117/6/2026
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.
ModificadaAlta (7.8)0.93%—Schneider-electric Interactive Graphical Scada System11/3/202117/6/2026
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to…
ModificadaAlta (7.8)0.88%—Schneider-electric Interactive Graphical Scada System11/3/202117/6/2026
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to…
ModificadaAlta (7.8)2.2%—Schneider-electric Interactive Graphical Scada System11/3/202117/6/2026
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)2.2%—Schneider-electric Interactive Graphical Scada System11/3/202117/6/2026
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to…
ModificadaAlta (7.8)2.5%—Schneider-electric Interactive Graphical Scada System19/11/202017/6/2026
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)2.5%—Schneider-electric Interactive Graphical Scada System19/11/202017/6/2026
A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)2.5%—Schneider-electric Interactive Graphical Scada System19/11/202017/6/2026
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)2.5%—Schneider-electric Interactive Graphical Scada System19/11/202017/6/2026
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)2.5%—Schneider-electric Interactive Graphical Scada System19/11/202017/6/2026
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)2.4%—Schneider-electric Interactive Graphical Scada System19/11/202017/6/2026
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)1.7%—Schneider-electric Interactive Graphical Scada System19/11/202017/6/2026
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
ModificadaAlta (7.8)1.7%—Schneider-electric Interactive Graphical Scada System19/11/202017/6/2026
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.