Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2980▼ 83 respecto a la semana anterior
Críticas / altas1452▲ 101 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)353▼ 157 respecto a la semana anterior
83 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Analizada | Alta (8.7) | 1.1% | — | Tenda AC7 Firmware | 3/3/2025 | 17/6/2026 | A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has… | |
| Analizada | Media (5.3) | 1.8% | — | Tenda AC7 Firmware | 2/3/2025 | 17/6/2026 | A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 28/10/2024 | 17/6/2026 | Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 28/10/2024 | 17/6/2026 | Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. | |
| Analizada | Alta (7.1) | 0.80% | — | Tenda Ac15 FirmwareTenda AC7 FirmwareTenda Ac10u FirmwareTenda Ac500 Firmware+6 | 23/10/2024 | 17/6/2026 | A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may… | |
| Analizada | Crítica (9.8) | 0.81% | — | Tenda AC7 Firmware | 17/4/2024 | 17/6/2026 | Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. | |
| Analizada | Alta (8.8) | 1.8% | — | Tenda AC7 Firmware | 17/4/2024 | 17/6/2026 | Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter. | |
| Analizada | Alta (8.8) | 1.8% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been… | |
| Analizada | Alta (8.8) | 1.8% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been… | |
| Analizada | Alta (8.8) | 7.8% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and… | |
| Analizada | Alta (8.8) | 1.9% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed… | |
| Analizada | Alta (8.8) | 1.6% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed… | |
| Analizada | Alta (8.8) | 1.7% | — | Tenda AC7 Firmware | 26/3/2024 | 17/6/2026 | A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been… | |
| Modificada | Crítica (9.8) | 0.84% | — | Tenda AC9 FirmwareTenda AC7 FirmwareTenda AC5 Firmware | 30/8/2023 | 17/6/2026 | Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. | |
| Modificada | Crítica (9.8) | 0.84% | — | Tenda AC9 FirmwareTenda AC7 FirmwareTenda AC5 Firmware | 30/8/2023 | 17/6/2026 | Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. | |
| Modificada | Crítica (9.8) | 0.84% | — | Tenda AC7 Firmware | 30/8/2023 | 17/6/2026 | Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg. | |
| Modificada | Crítica (9.8) | 0.84% | — | Tenda AC7 FirmwareTenda AC5 Firmware | 30/8/2023 | 17/6/2026 | Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. | |
| Modificada | Crítica (9.8) | 1.1% | — | Tenda AC9 FirmwareTenda AC7 FirmwareTenda AC5 Firmware | 30/8/2023 | 17/6/2026 | Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. |