Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2715▼ 529 respecto a la semana anterior
Críticas / altas1290▼ 220 respecto a la semana anterior
Nueva explotación activa (KEV)3▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)225▼ 276 respecto a la semana anterior
787 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 0.59% | — | Schneider-electric Powerlogic Ion7400 FirmwareSchneider-electric Powerlogic Ion7650 FirmwareSchneider-electric Powerlogic Ion7700 FirmwareSchneider-electric Powerlogic Ion7300 Firmware+8 | 19/2/2021 | 17/6/2026 | A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet… | |
| Modificada | Media (4.5) | 0.34% | — | Schneider-electric Powerlogic Ion7400 FirmwareSchneider-electric Powerlogic Ion7650 FirmwareSchneider-electric Powerlogic Ion8600 FirmwareSchneider-electric Powerlogic Ion8650 Firmware+6 | 19/2/2021 | 17/6/2026 | A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface. | |
| Modificada | Alta (7.8) | 3.9% | — | Schneider-electric Ecostruxure Power Build - Rapsody | 26/1/2021 | 17/6/2026 | A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | |
| Modificada | Alta (7.8) | 3.5% | — | Schneider-electric Ecostruxure Power Build - Rapsody | 26/1/2021 | 17/6/2026 | A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | |
| Modificada | Crítica (9.8) | 2.1% | — | Schneider-electric Ecostruxure Operator Terminal ExpertSchneider-electric Pro-face Blue | 26/1/2021 | 17/6/2026 | A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI. | |
| Modificada | Alta (8.6) | 1.4% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Unity PRO | 11/12/2020 | 17/6/2026 | A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. | |
| Modificada | Media (5.3) | 1.1% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+15 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause denial of HTTP and FTP services when a… | |
| Modificada | Alta (7.5) | 1.3% | — | Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+12 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over… | |
| Modificada | Alta (7.5) | 1.3% | — | Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+16 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over… | |
| Modificada | Media (5.3) | 0.91% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+16 | 11/12/2020 | 17/6/2026 | A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted… | |
| Modificada | Crítica (9.8) | 2.3% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+19 | 11/12/2020 | 17/6/2026 | A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller… | |
| Modificada | Alta (7.5) | 1.2% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+16 | 11/12/2020 | 17/6/2026 | A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a… | |
| Modificada | Alta (7.5) | 1.4% | — | Schneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep582040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Modicon M580 Bmep585040 Firmware+15 | 11/12/2020 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over… | |
| Modificada | Alta (7.5) | 1.2% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+6 | 11/12/2020 | 17/6/2026 | A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to… | |
| Modificada | Alta (7.5) | 1.5% | — | Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+17 | 11/12/2020 | 17/6/2026 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause… | |
| Modificada | Media (6.8) | 1.1% | — | Schneider-electric Modicon M258 FirmwareSchneider-electric SomachineSchneider-electric Somachine Motion | 11/12/2020 | 17/6/2026 | A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not… | |
| Modificada | Alta (7.8) | 0.31% | — | Schneider-electric Ecostruxure GEO Scada Expert 2019Schneider-electric Ecostruxure GEO Scada Expert 2020 | 11/12/2020 | 17/6/2026 | A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1),… | |
| Modificada | Media (6.5) | 1.1% | — | Schneider-electric Easergy T300 Firmware | 11/12/2020 | 17/6/2026 | A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to trick a user into initiating an unintended action. | |
| Modificada | Alta (7.5) | 0.58% | — | Schneider-electric Easergy T300 Firmware | 11/12/2020 | 17/6/2026 | A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. | |
| Modificada | Alta (7.5) | 0.51% | — | Schneider-electric Easergy T300 Firmware | 11/12/2020 | 17/6/2026 | A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. | |
| Modificada | Crítica (9.8) | 2.3% | — | Schneider-electric Easergy T300 Firmware | 11/12/2020 | 17/6/2026 | A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently. | |
| Modificada | Media (5.5) | 0.73% | — | Schneider-electric Modicon M221 Firmware | 11/12/2020 | 17/6/2026 | A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would… | |
| Modificada | Crítica (9.8) | 1.4% | — | Schneider-electric Acti9 Smartlink SI D FirmwareSchneider-electric Acti9 Smartlink SI B FirmwareSchneider-electric Acti9 Powertag Link FirmwareSchneider-electric Acti9 Powertag Link HD Firmware+3 | 1/12/2020 | 17/6/2026 | A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login. | |
| Modificada | Alta (8.8) | 1.3% | — | Schneider-electric Ecostruxure Energy ExpertSchneider-electric Ecostruxure Power Monitoring ExpertSchneider-electric Power ManagerSchneider-electric Powerscada Expert With Advanced Reporting AND Dashboards+1 | 1/12/2020 | 17/6/2026 | A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level. | |
| Modificada | Media (5.4) | 0.63% | — | Schneider-electric Ecostruxure Energy ExpertSchneider-electric Ecostruxure Power Monitoring ExpertSchneider-electric Power ManagerSchneider-electric Powerscada Expert With Advanced Reporting AND Dashboards+1 | 1/12/2020 | 17/6/2026 | A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an… |