CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.8)0.51%—Schneider-electric Interactive Graphical Scada System23/3/202017/6/2026
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
ModificadaAlta (7.5)4.1%—Schneider-electric Interactive Graphical Scada System23/3/202017/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.
ModificadaCrítica (9.8)2.6%—Emerson Openenterprise Scada Server19/2/202017/6/2026
A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server.
ModificadaCrítica (9.8)6.7%—Yokogawa Centum CS 1000 FirmwareYokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP Firmware+175/2/202017/6/2026
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and…
ModificadaCrítica (9.8)4.2%—Yokogawa Centum CS 1000 FirmwareYokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP Firmware+175/2/202017/6/2026
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and…
ModificadaCrítica (9.8)4.2%—Yokogawa Centum CS 1000 FirmwareYokogawa Centum CS 3000 FirmwareYokogawa Centum CS 3000 Entry FirmwareYokogawa Centum VP Firmware+175/2/202017/6/2026
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and…
ModificadaAlta (7.8)0.17%—Schneider-electric Clearscada6/1/202017/6/2026
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that…
ModificadaMedia (6.1)1.0%—Scadabr14/10/201917/6/2026
A cross-site scripting (XSS) vulnerability in the login form (/ScadaBR/login.htm) in ScadaBR 1.0CE allows a remote attacker to inject arbitrary web script or HTML via the username or password parameter.
ModificadaMedia (6.1)0.82%—Scadabr15/9/201917/6/2026
ScadaBR 1.0CE, and 1.1.x through 1.1.0-RC, has XSS via a request for a nonexistent resource, as demonstrated by the dwr/test/ PATH_INFO.
ModificadaBaja (3.3)0.86%—Laquisscada Scada5/8/201917/6/2026
Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is…
ModificadaAlta (7.8)1.0%—Laquisscada Scada5/8/201917/6/2026
A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is…
ModificadaAlta (7.8)1.3%—Schneider-electric Interactive Graphical Scada System15/7/201917/6/2026
A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.
ModificadaAlta (7.8)0.38%—Schneider-electric CitectscadaSchneider-electric Scada Expert Vijeo Citect31/5/201917/6/2026
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
ModificadaAlta (7.1)1.1%—Laquisscada Laquis Scada27/3/201917/6/2026
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration.
ModificadaAlta (7.8)1.2%—Lcds Laquis Scada27/3/201917/6/2026
Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.
ModificadaCrítica (9.8)2.0%—Advantech Webaccess/scada5/2/201917/6/2026
WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.
ModificadaAlta (8.6)1.9%—Advantech Webaccess/scada5/2/201917/6/2026
WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information.
ModificadaCrítica (9.8)2.8%—Advantech Webaccess/scada5/2/201917/6/2026
WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.
ModificadaAlta (7.8)2.7%—Lcds Laquis Scada5/2/201917/6/2026
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.
ModificadaAlta (7.8)2.7%—Lcds Laquis Scada5/2/201917/6/2026
LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.
ModificadaMedia (5.3)8.8%—Lcds Laquis Scada5/2/201917/6/2026
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.
ModificadaCrítica (9.8)2.4%—Lcds Laquis Scada5/2/201917/6/2026
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
ModificadaCrítica (9.8)2.5%—Lcds Laquis Scada5/2/201917/6/2026
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server.
ModificadaAlta (8.8)2.0%—Lcds Laquis Scada5/2/201917/6/2026
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.
ModificadaMedia (5.3)39%—Lcds Laquis Scada5/2/201917/6/2026
LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.