Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2696▼ 543 respecto a la semana anterior
Críticas / altas1264▼ 228 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)262▼ 241 respecto a la semana anterior
–

694 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)1.8%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+615/8/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the…
ModificadaCrítica (9.8)1.9%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+615/8/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or…
ModificadaAlta (8.8)0.28%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+815/8/201917/6/2026
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless…
ModificadaMedia (5.9)0.98%—Siemens Simatic ET 200sp Open Controller CPU 1515sp PC FirmwareSiemens Simatic ET 200sp Open Controller CPU 1515sp PC2 FirmwareSiemens Simatic S7-1200 CPU 1211c FirmwareSiemens Simatic S7-1200 CPU 1212c Firmware+1613/8/201917/6/2026
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC…
ModificadaAlta (7.5)3.5%—Redhat UndertowRedhat Jboss Data GridRedhat Jboss Enterprise Application PlatformRedhat Openshift Application Runtimes+225/7/201917/6/2026
undertow before version 2.0.23.Final is vulnerable to an information leak issue. Web apps may have their directory structures predicted through requests without trailing slashes via the api.
ModificadaAlta (7.2)1.3%—Siemens Simatic PCS 7Siemens Simatic WinccSiemens Simatic Wincc Runtime11/7/201917/6/2026
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC…
ModificadaCrítica (9.8)3.0%—Redhat UndertowRedhat VirtualizationRedhat Virtualization HostRedhat Jboss Data Grid+212/6/201917/6/2026
A vulnerability was found in Undertow web server before 2.0.21. An information exposure of plain text credentials through log files because Connectors.executeRootHandler:402 logs the HttpServerExchange object at ERROR level using UndertowLogger.REQUEST_LOGGER.undertowRequestFailed(t, exchange)
ModificadaMedia (6.5)4.8%—Adobe Flash Player Desktop RuntimeAdobe Flash Player24/5/201917/6/2026
Flash Player Desktop Runtime versions 32.0.0.114 and earlier, Flash Player for Google Chrome versions 32.0.0.114 and earlier, and Flash Player for Microsoft Edge and Internet Explorer 11 versions 32.0.0.114 and earlier have an out-of-bounds read vulnerability. Successful exploitation could lead to information…
ModificadaAlta (7.5)3.2%—Adobe Flash Player Desktop RuntimeAdobe Flash Player23/5/201917/6/2026
Adobe Flash Player versions 32.0.0.156 and earlier, 32.0.0.156 and earlier, and 32.0.0.156 and earlier have an out-of-bounds read vulnerability. Successful exploitation could lead to information disclosure .
ModificadaCrítica (9.8)6.2%—Adobe Flash Player Desktop RuntimeAdobe Flash Player23/5/201917/6/2026
Adobe Flash Player versions 32.0.0.156 and earlier, 32.0.0.156 and earlier, and 32.0.0.156 and earlier have an use after free vulnerability. Successful exploitation could lead to arbitrary code execution.
ModificadaAlta (8.8)9.7%—Adobe Flash Player Desktop RuntimeAdobe Flash PlayerRedhat Enterprise Linux DesktopRedhat Enterprise Linux Server+122/5/201917/6/2026
Adobe Flash Player versions 32.0.0.171 and earlier, 32.0.0.171 and earlier, and 32.0.0.171 and earlier have a use after free vulnerability. Successful exploitation could lead to arbitrary code execution.
ModificadaMedia (5.4)0.88%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+814/5/201917/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime…
ModificadaMedia (6.5)1.7%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+814/5/201917/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime…
ModificadaCrítica (9.1)2.7%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+814/5/201917/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime…
ModificadaAlta (8.8)1.9%—Siemens Simatic PCS 7Siemens Simatic WinccSiemens Simatic Wincc (tia Portal)Siemens Simatic Wincc Runtime Professional14/5/201917/6/2026
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA…
ModificadaMedia (5.5)0.27%—Siemens Simatic PCS 7Siemens Simatic WinccSiemens Simatic Wincc (tia Portal)Siemens Simatic Wincc Runtime Professional14/5/201917/6/2026
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA…
ModificadaAlta (8.8)1.5%—Siemens Simatic PCS 7Siemens Simatic WinccSiemens Simatic Wincc (tia Portal)Siemens Simatic Wincc Runtime Professional14/5/201917/6/2026
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA…
ModificadaAlta (7.5)1.6%—Siemens Simatic Cp443-1 OPC UA FirmwareSiemens Simatic ET 200 Open Controller CPU 1515sp PC2 FirmwareSiemens Simatic IPC Diagmonitor FirmwareSiemens Simatic NET PC Software Firmware+2317/4/201917/6/2026
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl.…
ModificadaAlta (7.5)1.4%—Siemens Cp1604 FirmwareSiemens Cp1616 FirmwareSiemens Simatic Rf185c FirmwareSiemens Simatic Cp343-1 Advanced Firmware+4917/4/201917/6/2026
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the…
ModificadaAlta (8.8)1.4%—Cloudfoundry Container Runtime8/3/201917/6/2026
Cloud Foundry Container Runtime, versions prior to 0.28.0, deploys K8s worker nodes that contains a configuration file with IAAS credentials. A malicious user with access to the k8s nodes can obtain IAAS credentials allowing the user to escalate privileges to gain access to the IAAS account.
ModificadaAlta (8.8)0.67%—Cloudfoundry Container Runtime8/3/201917/6/2026
Cloud Foundry Container Runtime, versions prior to 0.29.0, deploys Kubernetes clusters utilize the same CA (Certificate Authority) to sign and trust certs for ETCD as used by the Kubernetes API. This could allow a user authenticated with a cluster to request a signed certificate leveraging the Kubernetes CSR…
ModificadaAlta (7.5)3.0%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1419/2/201917/6/2026
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
ModificadaAlta (7.5)2.6%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+1119/2/201917/6/2026
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.
ModificadaCrítica (9.8)1.3%—Codesys Control FOR Beaglebone SLCodesys Control FOR Empc-a/imx6 SLCodesys Control FOR Iot2000 SLCodesys Control FOR Linux SL+829/1/201917/6/2026
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.
ModificadaAlta (8.8)1.7%—Siemens Simatic HMI Comfort Panels FirmwareSiemens Simatic HMI Comfort Outdoor Panels FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens Simatic HMI KTP Mobile Panels Ktp700 Firmware+813/12/201817/6/2026
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14),…