ModificadaAlta (7.2)2.1%—Schneider-electric Ecostruxure Energy ExpertSchneider-electric Ecostruxure Power Monitoring ExpertSchneider-electric Power ManagerSchneider-electric Powerscada Expert With Advanced Reporting AND Dashboards+11/12/202017/6/2026
A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.
ModificadaAlta (7.5)1.9%—Schneider-electric Ecostruxure Control Expert19/11/202017/6/2026
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request…
ModificadaAlta (7.8)0.31%—Schneider-electric Operator Terminal Expert Runtime19/11/202017/6/2026
A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert.
ModificadaAlta (7.5)1.3%—Schneider-electric Ecostruxure Control Expert19/11/202017/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
ModificadaAlta (8.8)1.2%—Schneider-electric Ecostruxure Control Expert19/11/202017/6/2026
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.
ModificadaCrítica (9.8)2.8%—Schneider-electric Ecostruxure Control Expert19/11/202017/6/2026
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.
ModificadaAlta (7.8)0.33%—Schneider-electric Ecostruxure Control Expert19/11/202017/6/2026
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
ModificadaCrítica (9.8)2.3%—Schneider-electric Ecostruxure Operator Terminal Expert16/6/202017/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts.
ModificadaAlta (7.8)0.86%—SE Ecostruxure Operator Terminal Expert16/6/202017/6/2026
A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.
ModificadaMedia (5.5)0.88%—Schneider-electric Ecostruxure Operator Terminal Expert16/6/202017/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access outside of expected path folder when…
ModificadaAlta (7.8)1.3%—Schneider-electric Ecostruxure Operator Terminal Expert16/6/202017/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
ModificadaAlta (7.8)1.1%—Schneider-electric Ecostruxure Operator Terminal Expert16/6/202017/6/2026
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
ModificadaCrítica (9.8)1.6%—Schneider-electric Ecostruxure Machine ExpertSchneider-electric Somachine BasicSchneider-electric Modicon M100 FirmwareSchneider-electric Modicon M200 Firmware+122/4/202017/6/2026
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the…
ModificadaAlta (7.5)0.88%—Schneider-electric Ecostruxure Machine ExpertSchneider-electric SomachineSchneider-electric Somachine MotionSchneider-electric Modicon M218 Firmware+322/4/202017/6/2026
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.
ModificadaCrítica (9.8)0.69%—Schneider-electric Ecostruxure Machine ExpertSchneider-electric SomachineSchneider-electric Somachine MotionSchneider-electric Modicon M218 Firmware+322/4/202017/6/2026
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.
ModificadaCrítica (9.8)1.6%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Unity PROSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware23/3/202017/6/2026
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior…
ModificadaAlta (7.3)0.95%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Unity PROSchneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmeh584040 Firmware+196/1/202017/6/2026
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control…
ModificadaCrítica (9.8)1.9%—Equinoxce Control Expert23/12/201917/6/2026
Equinox Control Expert all versions, is vulnerable to an SQL injection attack, which may allow an attacker to remotely execute arbitrary code.
ModificadaMedia (6.5)1.3%—Clipsoft Rexpert30/10/201917/6/2026
ClipSoft REXPERT 1.0.0.527 and earlier version allows remote attacker to arbitrary file deletion by issuing a HTTP GET request with a specially crafted parameter. User interaction is required to exploit this vulnerability in that the target must visit a malicious web page.
ModificadaMedia (6.5)1.2%—Clipsoft Rexpert30/10/201917/6/2026
ClipSoft REXPERT 1.0.0.527 and earlier version allows remote attacker to upload arbitrary local file via the ActiveX method in RexViewerCtrl30.ocx. That could lead to disclosure of sensitive information. User interaction is required to exploit this vulnerability in that the target must visit a malicious web page.
ModificadaMedia (6.5)1.2%—Clipsoft Rexpert30/10/201917/6/2026
ClipSoft REXPERT 1.0.0.527 and earlier version allows directory traversal by issuing a special HTTP POST request with ../ characters. This could lead to create malicious HTML file, because they can inject a content with crafted template. User interaction is required to exploit this vulnerability in that the target…
ModificadaAlta (8.8)1.6%—Clipsoft Rexpert30/10/201917/6/2026
ClipSoft REXPERT 1.0.0.527 and earlier version allows arbitrary file creation and execution via report print function of rexpert viewer with modified XML document. User interaction is required to exploit this vulnerability in that the target must visit a malicious web page.
ModificadaMedia (6.5)1.2%—Clipsoft Rexpert30/10/201917/6/2026
ClipSoft REXPERT 1.0.0.527 and earlier version allows arbitrary file creation via a POST request with the parameter set to the file path to be written. This can be an executable file that is written to in the arbitrary directory. User interaction is required to exploit this vulnerability in that the target must visit…
ModificadaMedia (5.3)0.93%—Clipsoft Rexpert30/10/201917/6/2026
ClipSoft REXPERT 1.0.0.527 and earlier version have an information disclosure issue. When requesting web page associated with session, could leak username via session file path of HTTP response data. No authentication is required.
ModificadaAlta (7.5)2.0%—Wpexpertdeveloper WP Private Content Plus30/8/201917/6/2026