Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2698▼ 542 respecto a la semana anterior
Críticas / altas1273▼ 220 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)254▼ 248 respecto a la semana anterior
358 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Crítica (9.8) | 6.9% | — | Mitsubishielectric C Controller Module Setting AND Monitoring ToolMitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric Data Transfer+37 | 19/2/2021 | 17/6/2026 | Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all… | |
| Modificada | Crítica (9.8) | 3.9% | — | Mitsubishielectric C Controller Module Setting AND Monitoring ToolMitsubishielectric CPU Module Logging Configuration ToolMitsubishielectric CW ConfiguratorMitsubishielectric Data Transfer+37 | 19/2/2021 | 17/6/2026 | Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3… | |
| Modificada | Alta (8.8) | 1.2% | — | Tesla Solarcity Solar Monitoring Gateway | 18/2/2021 | 17/6/2026 | Tesla SolarCity Solar Monitoring Gateway through 5.46.43 has a "Use of Hard-coded Credentials" issue because Digi ConnectPort X2e uses a .pyc file to store the cleartext password for the python user account. | |
| Modificada | Crítica (9.8) | 3.2% | 💥 PoC | Lanatmservice M3 ATM Monitoring System | 10/12/2020 | 17/6/2026 | In Lan ATMService M3 ATM Monitoring System 6.1.0, a remote attacker able to use a default cookie value, such as PHPSESSID=LANIT-IMANAGER, can achieve control over the system because of Insufficient Session Expiration. | |
| Modificada | Media (5.3) | 1.5% | 💥 PoC | Lanatmservice M3 ATM Monitoring System | 10/12/2020 | 17/6/2026 | In Lan ATMService M3 ATM Monitoring System 6.1.0, due to a directory-listing vulnerability, a remote attacker can view log files, located in /websocket/logs/, that contain a user's cookie values and the predefined developer's cookie value. | |
| Modificada | Alta (8.8) | 1.3% | — | Schneider-electric Ecostruxure Energy ExpertSchneider-electric Ecostruxure Power Monitoring ExpertSchneider-electric Power ManagerSchneider-electric Powerscada Expert With Advanced Reporting AND Dashboards+1 | 1/12/2020 | 17/6/2026 | A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level. | |
| Modificada | Media (5.4) | 0.63% | — | Schneider-electric Ecostruxure Energy ExpertSchneider-electric Ecostruxure Power Monitoring ExpertSchneider-electric Power ManagerSchneider-electric Powerscada Expert With Advanced Reporting AND Dashboards+1 | 1/12/2020 | 17/6/2026 | A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an… | |
| Modificada | Alta (7.2) | 2.1% | — | Schneider-electric Ecostruxure Energy ExpertSchneider-electric Ecostruxure Power Monitoring ExpertSchneider-electric Power ManagerSchneider-electric Powerscada Expert With Advanced Reporting AND Dashboards+1 | 1/12/2020 | 17/6/2026 | A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage. | |
| Analizada | Alta (8.8) | 85% | 💥 Exploit | XstreamDebian LinuxNetapp SnapmanagerApache Activemq+11 | 16/11/2020 | 7/10/2026 | XStream before version 1.4.14 is vulnerable to Remote Code Execution.The vulnerability may allow a remote attacker to run arbitrary shell commands only by manipulating the processed input stream. Only users who rely on blocklists are affected. Anyone using XStream's Security Framework allowlist is not affected. The… | |
| Modificada | Alta (7.3) | 1.1% | — | Solarwinds Advanced Monitoring Agent | 7/6/2020 | 17/6/2026 | SolarWinds Advanced Monitoring Agent before 10.8.9 allows local users to gain privileges via a Trojan horse .exe file, because everyone can write to a certain .exe file. | |
| Modificada | Media (6.1) | 2.2% | — | Centreon Host-monitoring WidgetCentreon Tactical-overview WidgetCentreon Service-monitoring Widget | 27/5/2020 | 17/6/2026 | Cross-site scripting (XSS) vulnerability allows remote attackers to inject arbitrary web script or HTML via the widgetId parameter to host-monitoring/src/toolbar.php. This vulnerability is fixed in versions 1.6.4, 18.10.3, 19.04.3, and 19.0.1 of the Centreon host-monitoring widget; 1.6.4, 18.10.5, 19.04.3, 19.10.2 of… | |
| Modificada | Media (6.1) | 2.2% | — | Centreon Host-monitoring WidgetCentreon Tactical-overview WidgetCentreon Service-monitoring Widget | 27/5/2020 | 17/6/2026 | Cross-site scripting (XSS) vulnerability allows remote attackers to inject arbitrary web script or HTML via the widgetId parameter to service-monitoring/src/index.php. This vulnerability is fixed in versions 1.6.4, 18.10.3, 19.04.3, and 19.0.1 of the Centreon host-monitoring widget; 1.6.4, 18.10.5, 19.04.3, 19.10.2 of… | |
| Modificada | Media (6.1) | 2.2% | — | Centreon Host-monitoring WidgetCentreon Tactical-overview WidgetCentreon Service-monitoring Widget | 27/5/2020 | 17/6/2026 | Cross-site scripting (XSS) vulnerability allows remote attackers to inject arbitrary web script or HTML via the page parameter to service-monitoring/src/index.php. This vulnerability is fixed in versions 1.6.4, 18.10.3, 19.04.3, and 19.0.1 of the Centreon host-monitoring widget; 1.6.4, 18.10.5, 19.04.3, 19.10.2 of the… | |
| Modificada | Media (4.3) | 0.65% | — | CentreonCentreon Widget-host-monitoring | 27/5/2020 | 17/6/2026 | Centreon before 19.10.7 exposes Session IDs in server responses. | |
| Modificada | Crítica (9.8) | 4.1% | 💥 Exploit | Mikrotik-router-monitoring-system Project Mikrotik-router-monitoring-system | 16/5/2020 | 17/6/2026 | An issue was discovered in Mikrotik-Router-Monitoring-System through 2018-10-22. SQL Injection exists in check_community.php via the parameter community. | |
| Modificada | Alta (7) | 0.32% | — | IBM Tivoli Monitoring | 23/4/2020 | 17/6/2026 | IBM Tivoli Monitoring 6.3.0 could allow a local attacker to execute arbitrary code on the system. By placing a specially crafted file, an attacker could exploit this vulnerability to load other DLL files located in the same directory and execute arbitrary code on the system. IBM X-Force ID: 177083. | |
| Modificada | Alta (7.5) | 1.3% | — | IBM Tivoli Monitoring | 13/2/2020 | 17/6/2026 | IBM Tivoli Monitoring Service 6.3.0.7.3 through 6.3.0.7.10 could allow an unauthorized user to access and modify operation aspects of the ITM monitoring server possibly leading to an effective denial of service or disabling of the monitoring server. IBM X-Force ID: 167647. | |
| Modificada | Alta (7.5) | 2.1% | — | Percona Monitoring AND Management | 6/2/2020 | 17/6/2026 | pmm-server in Percona Monitoring and Management (PMM) 2.2.x before 2.2.1 allows unauthenticated denial of service. | |
| Modificada | Alta (8.8) | 1.7% | — | Bigswitch BIG Cloud FabricBigswitch BIG Monitoring FabricBigswitch Multi-cloud Director | 24/1/2020 | 17/6/2026 | An issue was discovered in Big Switch Big Monitoring Fabric 6.2 through 6.2.4, 6.3 through 6.3.9, 7.0 through 7.0.3, and 7.1 through 7.1.3; Big Cloud Fabric 4.5 through 4.5.5, 4.7 through 4.7.7, 5.0 through 5.0.1, and 5.1 through 5.1.4; and Multi-Cloud Director through 1.1.0. A read-only user can access sensitive… | |
| Modificada | Media (6.1) | 1.0% | — | Bigswitch BIG Cloud FabricBigswitch BIG Monitoring FabricBigswitch Multi-cloud Director | 24/1/2020 | 17/6/2026 | An issue was discovered in Big Switch Big Monitoring Fabric 6.2 through 6.2.4, 6.3 through 6.3.9, 7.0 through 7.0.3, and 7.1 through 7.1.3; Big Cloud Fabric 4.5 through 4.5.5, 4.7 through 4.7.7, 5.0 through 5.0.1, and 5.1 through 5.1.4; and Multi-Cloud Director through 1.1.0. An unauthenticated attacker may inject… | |
| Modificada | Alta (7.8) | 0.42% | — | Motex Lanscope ANMotex Lanscope CAT Client ProgramMotex Lanscope CAT Detection AgentMotex Lanscope CAT Server Monitoring Agent | 26/12/2019 | 17/6/2026 | Privilege escalation vulnerability in Multiple MOTEX products (LanScope Cat client program (MR) and LanScope Cat client program (MR)LanScope Cat detection agent (DA) prior to Ver.9.2.1.0, LanScope Cat server monitoring agent (SA, SAE) prior to Ver.9.2.2.0, LanScope An prior to Ver 2.7.7.0 (LanScope An 2 series), and… | |
| Modificada | Crítica (10) | 4.9% | — | Dell EMC Storage Monitoring AND Reporting | 26/11/2019 | 17/6/2026 | Dell EMC Storage Monitoring and Reporting version 4.3.1 contains a Java RMI Deserialization of Untrusted Data vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability by sending a crafted RMI request to execute arbitrary code on the target host. | |
| Modificada | Alta (7.5) | 1.7% | — | AUO Sunveillance Monitoring System & Data Recorder | 12/11/2019 | 17/6/2026 | AUO SunVeillance Monitoring System before v1.1.9e is vulnerable to mvc_send_mail.aspx (MailAdd parameter) SQL Injection. An Attacker can carry a SQL Injection payload to the server, allowing the attacker to read privileged data. This also affects the picture_manage_mvc.aspx plant_no parameter, the swapdl_mvc.aspx… | |
| Modificada | Crítica (9.8) | 2.1% | — | AUO Sunveillance Monitoring System & Data Recorder | 12/11/2019 | 17/6/2026 | An issue was discovered in Picture_Manage_mvc.aspx in AUO SunVeillance Monitoring System before v1.1.9e. There is an incorrect access control vulnerability that can allow an unauthenticated user to upload files via a modified authority parameter. | |
| Modificada | Media (6.1) | 2.2% | 💥 PoC | Redhat Hibernate ValidatorRedhat FuseRedhat Jboss Data GridRedhat Jboss Enterprise Application Platform+183 | 8/11/2019 | 25/8/2026 | A vulnerability was found in Hibernate-Validator. The SafeHtml validator annotation fails to properly sanitize payloads consisting of potentially malicious code in HTML comments and instructions. This vulnerability can result in an XSS attack. |