Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2783▼ 434 respecto a la semana anterior
Críticas / altas1335▼ 118 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)265▼ 243 respecto a la semana anterior
–

29 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)0.61%—Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 FirmwareSchneider-electric Modicon M340 Bmxp3420102 Firmware+1022/11/202217/6/2026
A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100…
ModificadaAlta (7.5)1.0%—Schneider-electric Modicon M340 Bmxp342020 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoc0401 Firmware+1011/2/202217/6/2026
A CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H),…
ModificadaAlta (7.5)1.0%—Schneider-electric Modicon M340 Bmxp342020 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoc0401 Firmware+1011/2/202217/6/2026
A CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules:…
ModificadaAlta (7.5)0.96%—Schneider-electric Modicon M340 Bmxp342020 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoc0401 Firmware+1011/2/202217/6/2026
A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when an attacker sends a HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet…
ModificadaAlta (8.8)0.36%—Schneider-electric Modicon M340 Bmxp342020 FirmwareSchneider-electric 140cpu65 FirmwareSchneider-electric Tsxp57 FirmwareSchneider-electric Bmxnoc0401 Firmware+64/2/202217/6/2026
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in. Affected Products: Modicon M340 CPUs: BMXP34 (All Versions), Modicon Quantum CPUs with integrated Ethernet…
ModificadaMedia (5.3)0.92%—Schneider-electric Modicon X80 Bmxnor0200h RTU Firmware11/6/202117/6/2026
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is…
ModificadaAlta (7.5)1.2%—Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp3420102 FirmwareSchneider-electric Modicon M340 Bmxp3420102cl Firmware+611/12/202017/6/2026
A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to…
ModificadaAlta (8.6)1.4%—Schneider-electric Bmxnor0200h Firmware17/9/201917/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP.
ModificadaAlta (7.5)2.1%—Schneider-electric Modicon M340 FirmwareSchneider-electric Bmxnor0200h Firmware17/9/201917/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.
ModificadaAlta (8.8)1.7%—Schneider-electric Bmxnor0200h Firmware17/9/201917/6/2026
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.
ModificadaMedia (5.4)0.56%—Schneider-electric Bmxnoc0401 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoe0110h Firmware+721/3/201917/6/2026
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC…
ModificadaMedia (5.4)0.87%—Schneider-electric Bmxnoc0401 FirmwareSchneider-electric Bmxnoe0100 FirmwareSchneider-electric Bmxnoe0110 FirmwareSchneider-electric Bmxnoe0110h Firmware+721/3/201917/6/2026
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser…
ModificadaAlta (7.5)1.4%—Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware17/12/201817/6/2026
An Improper Check for Unusual or Exceptional Conditions vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where an unauthenticated user can send a specially crafted XML data via a POST request to cause the web server to become unavailable
ModificadaAlta (7.5)3.7%—Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware17/12/201817/6/2026
An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses in a way that exposes security-relevant information about the state of the product, such as whether a particular…
ModificadaMedia (6.1)0.86%—Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware17/12/201817/6/2026
A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing.
ModificadaAlta (8.8)0.64%—Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware30/11/201817/6/2026
An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a password change on…
ModificadaAlta (7.5)2.4%—Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware30/11/201817/6/2026
Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a denial of service can occur for ~1 minute by sending a specially crafted HTTP request.
ModificadaCrítica (9.8)3.5%—Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware30/11/201817/6/2026
An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the change password function of the web server
ModificadaMedia (6.1)0.90%—Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware30/11/201817/6/2026
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially…
ModificadaCrítica (9.8)2.5%—Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware30/11/201817/6/2026
An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the password delete function of the web server.
ModificadaAlta (7.5)1.3%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
ModificadaCrítica (9.8)2.1%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
ModificadaCrítica (9.8)1.5%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
ModificadaAlta (7.5)1.3%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.
ModificadaCrítica (9.8)1.9%—Schneider-electric Bmxnor0200 FirmwareSchneider-electric Bmxnor0200h FirmwareSchneider-electric 140cpu65150 FirmwareSchneider-electric 140cpu31110 Firmware+5318/4/201817/6/2026
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.