Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2860▼ 336 respecto a la semana anterior
Críticas / altas1383▼ 43 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)296▼ 214 respecto a la semana anterior
27 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (4.9) | 0.85% | — | Wago 750-331 FirmwareWago 750-8202 FirmwareWago 750-8202/000-011 FirmwareWago 750-8202/000-012 Firmware+72 | 26/6/2023 | 17/6/2026 | Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a specifically crafted packet to the CODESYS V2 runtime. | |
| Modificada | Media (4.9) | 0.79% | — | Wago 750-331 FirmwareWago 750-8202 FirmwareWago 750-8202/000-011 FirmwareWago 750-8202/000-012 Firmware+72 | 26/6/2023 | 17/6/2026 | Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a malformed packet. | |
| Analizada | Alta (7.8) | 0.17% | — | Pilz PMCCodesys Control FOR BeagleboneCodesys Control FOR Empc-a/imx6Codesys Control FOR Iot2000+60 | 26/12/2022 | 17/6/2026 | In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device. | |
| Modificada | Crítica (9.8) | 0.85% | — | Wago 750-8100 FirmwareWago 750-8101 FirmwareWago 750-8101/025-000 FirmwareWago 750-8102 Firmware+45 | 9/11/2022 | 17/6/2026 | In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory. | |
| Modificada | Alta (7.5) | 1.1% | — | Wago 750-8100 FirmwareWago 750-8101 FirmwareWago 750-8101/025-000 FirmwareWago 750-8102 Firmware+45 | 9/11/2022 | 17/6/2026 | In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service. | |
| Modificada | Alta (8.2) | 0.82% | — | Wago 750-8100 FirmwareWago 750-8101 FirmwareWago 750-8101/025-000 FirmwareWago 750-8102 Firmware+45 | 9/11/2022 | 17/6/2026 | In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read. | |
| Modificada | Crítica (9.1) | 1.1% | — | Wago 750-8100 FirmwareWago 750-8101 FirmwareWago 750-8101/025-000 FirmwareWago 750-8102 Firmware+45 | 9/11/2022 | 17/6/2026 | In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS. | |
| Modificada | Media (5.4) | 0.48% | — | Wago 750-8100 FirmwareWago 750-8101 FirmwareWago 750-8102 FirmwareWago 751-9301 Firmware+21 | 9/3/2022 | 17/6/2026 | Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised. | |
| Analizada | Media (6.5) | 0.85% | — | Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+26 | 26/10/2021 | 17/6/2026 | A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition. | |
| Analizada | Alta (8.1) | 0.88% | — | Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+26 | 26/10/2021 | 17/6/2026 | A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite. | |
| Analizada | Alta (7.5) | 2.7% | — | Wago 750-8202 FirmwareWago 750-8203 FirmwareWago 750-8204 FirmwareWago 750-8206 Firmware+11 | 26/10/2021 | 17/6/2026 | In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC. | |
| Analizada | Alta (7.5) | 14% | — | Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+24 | 26/10/2021 | 17/6/2026 | In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests may cause a Null pointer dereference in the CODESYS web server and may result in a denial-of-service condition. | |
| Analizada | Alta (7.5) | 0.93% | — | Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+24 | 26/10/2021 | 17/6/2026 | In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests can trigger a parser error. Since the parser result is not checked under all conditions, a pointer dereference with an invalid address can occur. This leads to a denial of service situation. | |
| Analizada | Crítica (9.1) | 1.1% | — | Wago 750-823 FirmwareWago 750-829 FirmwareWago 750-831 FirmwareWago 750-832 Firmware+24 | 26/10/2021 | 17/6/2026 | Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22. | |
| Analizada | Alta (7.5) | 8.4% | — | Wago 750-8214 FirmwareWago 750-8216 FirmwareWago 750-8217 FirmwareWago 750-8213 Firmware+24 | 26/10/2021 | 17/6/2026 | Crafted web server requests may cause a heap-based buffer overflow and could therefore trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22. | |
| Analizada | Alta (7.5) | 7.2% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+25 | 25/5/2021 | 17/6/2026 | CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation. | |
| Analizada | Crítica (9.1) | 1.2% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+24 | 25/5/2021 | 17/6/2026 | CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Read. | |
| Analizada | Crítica (9.8) | 1.2% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+24 | 25/5/2021 | 17/6/2026 | CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write. | |
| Analizada | Crítica (9.8) | 1.2% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+24 | 25/5/2021 | 17/6/2026 | CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check. | |
| Analizada | Alta (7.5) | 1.0% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+24 | 25/5/2021 | 17/6/2026 | CODESYS V2 Web-Server before 1.1.9.20 has a a Buffer Copy without Checking the Size of the Input. | |
| Analizada | Crítica (9.8) | 1.4% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+24 | 25/5/2021 | 17/6/2026 | CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. | |
| Analizada | Crítica (9.8) | 1.3% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+24 | 25/5/2021 | 17/6/2026 | CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow. | |
| Analizada | Crítica (9.8) | 1.3% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+24 | 25/5/2021 | 17/6/2026 | CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow. | |
| Analizada | Alta (7.5) | 7.4% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+25 | 25/5/2021 | 17/6/2026 | CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow. | |
| Analizada | Media (5.3) | 0.27% | — | Wago 750-893 FirmwareWago 750-891 FirmwareWago 750-890 FirmwareWago 750-889 Firmware+24 | 25/5/2021 | 17/6/2026 | CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command. |