CVE-2026-87662
Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control characters and shell metacharacters in fields like the host or file path are not stripped or sanitized, an attacker can execute arbitrary shell commands with the firmware management daemon's elevated privileges.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7
Probabilidad de explotación (EPSS)
FIRST aún no ha puntuado esta CVE (habitual en CVEs muy recientes o rechazadas).
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution85 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation75 %
AV:L + UI:P indica explotación en cliente (T1203). El texto describe inyección de comandos shell sin sanitizar parámetros en solicitudes de actualización, permitiendo ejecución arbitraria con privilegios elevados del demonio de gestión de firmware (T1059 + T1068).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-87662",
"cveTags": [],
"metrics": {
"cvssMetricV40": [
{
"type": "Secondary",
"source": "sirt@brocade.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "sirt@brocade.com",
"affectedData": [
{
"vendor": "Brocade",
"product": "Fabric OS",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "9.2.2d",
"versionType": "Brocade FabricOS"
},
{
"status": "affected",
"version": "10.0.0",
"versionType": "Brocade FabricOS",
"lessThanOrEqual": "10.0.0a1"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-10-08T05:17:05.433",
"references": [
{
"url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39162",
"source": "sirt@brocade.com"
}
],
"vulnStatus": "Received",
"weaknesses": [
{
"type": "Secondary",
"source": "sirt@brocade.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control characters and shell metacharacters in fields like the host or file path are not stripped or sanitized, an attacker can execute arbitrary shell commands with the firmware management daemon's elevated privileges."
}
],
"lastModified": "2026-10-08T05:17:05.433",
"sourceIdentifier": "sirt@brocade.com"
}