CVE-2026-8359
When processing a request with a URL path starting with /status or /sysinfo, WOSHttpStatusModule.dll is to be loaded to handle such URL patterns. The WOSBin_LoadHttpModule function in the dll would be called to set up a "module" object for that module. However, WOSHttpStatusModule.dll is not present in the installation. As a result, a function pointer to WOSBin_LoadHttpModule (which would have been in the export table in WOSHttpStatusModule.dll) is set to NULL, resulting in calling a function at address 0.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.46%
- Percentil entre todas las CVEs puntuadas: 38
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access90 % - Impacto principal
T1499.004Application or System Exploitationimpact85 %
Vulnerabilidad de DoS en aplicación web expuesta (AV:N/PR:N/UI:N); llamada a puntero NULL causa crash (CWE-476). Vector CVSS indica impacto de disponibilidad alto (A:H).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-476
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-8359",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-8359",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-05-27T20:26:08.783283Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "vulnreport@tenable.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "vulnreport@tenable.com",
"affectedData": [
{
"vendor": "Gladinet",
"product": "Triofox",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "17.3.10565.57509",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-05-27T20:16:42.590",
"references": [
{
"url": "https://www.tenable.com/security/research/TRA-2026-45",
"source": "vulnreport@tenable.com"
},
{
"url": "https://www.tenable.com/security/research/TRA-2026-45",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "vulnreport@tenable.com",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "When processing a request with a URL path starting with /status or /sysinfo, WOSHttpStatusModule.dll is to be loaded to handle such URL patterns. The WOSBin_LoadHttpModule function in the dll would be called to set up a \"module\" object for that module. However, WOSHttpStatusModule.dll is not present in the installation. As a result, a function pointer to WOSBin_LoadHttpModule (which would have been in the export table in WOSHttpStatusModule.dll) is set to NULL, resulting in calling a function at address 0."
}
],
"lastModified": "2026-06-17T11:03:50.683",
"sourceIdentifier": "vulnreport@tenable.com"
}