CVE-2026-80276

Estado: AplazadaAlta (7.5)—

Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface that does not require authentication. Through this interface, sensitive device configuration data - including the Remote Configuration Password - can be read in cleartext by a remote, unauthenticated attacker.

CVSS

Probabilidad de explotación (EPSS)

FIRST aún no ha puntuado esta CVE (habitual en CVEs muy recientes o rechazadas).

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-80276",
  "cveTags": [],
  "metrics": {
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "db4dfee8-a97e-4877-bfae-eba6d14a2166",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "db4dfee8-a97e-4877-bfae-eba6d14a2166",
      "affectedData": [
        {
          "vendor": "Comelit Group S.p.A.",
          "product": "1456B Multi-User Gateway",
          "versions": [
            {
              "status": "affected",
              "version": "2.9.1"
            },
            {
              "status": "affected",
              "version": "2.10.0"
            }
          ],
          "platforms": [
            "Firmware"
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2026-10-01T06:17:10.430",
  "references": [
    {
      "url": "https://pro.comelitgroup.com/en-us/product/1456B",
      "source": "db4dfee8-a97e-4877-bfae-eba6d14a2166"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "db4dfee8-a97e-4877-bfae-eba6d14a2166",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface that does not require authentication. Through this interface, sensitive device configuration data - including the Remote Configuration Password - can be read in cleartext by a remote, unauthenticated attacker."
    }
  ],
  "lastModified": "2026-10-01T13:04:49.340",
  "sourceIdentifier": "db4dfee8-a97e-4877-bfae-eba6d14a2166"
}