CVE-2026-78488
Estado: AnalizadaMedia (6.5)—
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 4.81%
- Percentil entre todas las CVEs puntuadas: 92
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-78488",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-78488",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-09-09T14:42:14.602938Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security_alert@emc.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "security_alert@emc.com",
"affectedData": [
{
"vendor": "Dell",
"product": "Secure Connect Gateway 5.0 - Application",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "5.36.00.00 or later",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Dell",
"product": "Secure Connect Gateway 5.0 - Appliance",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "5.36.00.16 or later",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-09-07T15:17:31.790",
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-in/000503426/dsa-2026-382-security-update-for-dell-secure-connect-gateway-virtual-edition-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9",
"tags": [
"Vendor Advisory"
],
"source": "security_alert@emc.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "security_alert@emc.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"lastModified": "2026-09-11T21:22:54.260",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:secure_connect_gateway:*:*:*:*:application:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7978D545-2FDA-4B19-B0A5-F87E87EE8A59",
"versionEndExcluding": "5.36.00.00"
},
{
"criteria": "cpe:2.3:a:dell:secure_connect_gateway:*:*:*:*:virtual:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D6766A93-993A-40A7-9766-F830A1AE4C80",
"versionEndExcluding": "5.36.00.16"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security_alert@emc.com"
}