Estado: Pendiente de análisisMedia (5)—
An issue that could allow a dashboard configuration to be viewed from outside of the authorized organization scope has been resolved. This is an instance of CWE-269: Improper Privilege Management, and has an estimated CVSS score of CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N (5.0, Medium). This issue was fixed in version v4.0.260416.0 of the runZero Platform.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N
- Puntuación base: 5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.28%
- Percentil entre todas las CVEs puntuadas: 19
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-269
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-7778",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "44488dab-36db-4358-99f9-bc116477f914",
"ssvcData": {
"role": "CNA",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3"
}
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-7778",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-05-05T14:41:44.344687Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "44488dab-36db-4358-99f9-bc116477f914",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 3.1
}
]
},
"affected": [
{
"source": "44488dab-36db-4358-99f9-bc116477f914",
"affectedData": [
{
"vendor": "runZero",
"product": "Platform",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "4.0.260416.0",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-05-05T14:16:09.473",
"references": [
{
"url": "https://help.runzero.com/docs/release-notes/#402604160",
"source": "44488dab-36db-4358-99f9-bc116477f914"
},
{
"url": "https://www.runzero.com/advisories/runzero-platform-dashboard-configuration-exposure-cve-2026-7778/",
"source": "44488dab-36db-4358-99f9-bc116477f914"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "44488dab-36db-4358-99f9-bc116477f914",
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue that could allow a dashboard configuration to be viewed from outside of the authorized organization scope has been resolved. This is an instance of CWE-269: Improper Privilege Management, and has an estimated CVSS score of CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N (5.0, Medium). This issue was fixed in version v4.0.260416.0 of the runZero Platform."
}
],
"lastModified": "2026-06-17T11:02:56.833",
"sourceIdentifier": "44488dab-36db-4358-99f9-bc116477f914"
}