« Volver al listado

CVE-2026-71920

Estado: AplazadaMedia (6.9)—

Multiple DrayTek VigorSwitch models contain a null pointer dereference vulnerability in the formlogout function. The vulnerability is caused by missing checks for an empty or absent Cookie header before string handling. A remote attacker can trigger this vulnerability via a crafted request to crash the service and cause a denial of service. Exploitation requires valid administrative credentials for the device's web management interface.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-71920",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-71920",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-08-24T18:17:16.143303Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.2
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 6.9,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@vulncheck.com",
      "affectedData": [
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G2540xs",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P2540xs",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch FX2120",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G2282x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.10.6",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P2282x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.10.6",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch Q2300x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.10.7",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch PQ2300xb",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.10.7",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G2542x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.10.6",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P2542x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.10.6",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P2542xh",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.10.6",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch PX2060",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G1280",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P1280",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P1281x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G1282",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P1282",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G2121",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P2121",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch PQ2121x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch Q2121x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G2280x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P2280x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch Q2200x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch PQ2200xb",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G2100",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P2100",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch G2540x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "DrayTek Corporation",
          "product": "VigorSwitch P2540x",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.9.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-08-24T18:17:06.847",
  "references": [
    {
      "url": "https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/",
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-null-pointer-dereference-via-formlogout",
      "source": "disclosure@vulncheck.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@vulncheck.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple DrayTek VigorSwitch models contain a null pointer dereference vulnerability in the formlogout function. The vulnerability is caused by missing checks for an empty or absent Cookie header before string handling. A remote attacker can trigger this vulnerability via a crafted request to crash the service and cause a denial of service. Exploitation requires valid administrative credentials for the device's web management interface."
    }
  ],
  "lastModified": "2026-08-26T17:08:22.300",
  "sourceIdentifier": "disclosure@vulncheck.com"
}