CVE-2026-68959
Estado: AplazadaMedia (5.8)—
SKYSEA Client View and SKYMEC IT Manager contain a path traversal vulnerability. If this vulnerability is exploited, an attacker who can log in to a Windows system on which the affected product is installed may be able to execute arbitrary code on another Windows system that has the affected products installed and can receive UDP packets from that system. Note that this vulnerability is due to an incomplete fix for CVE-2024-41726.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.65%
- Percentil entre todas las CVEs puntuadas: 50
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-25
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-68959",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-68959",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-08-25T19:51:44.725770Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 8.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.8,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "vultures@jpcert.or.jp",
"affectedData": [
{
"vendor": "Sky Co., LTD.",
"product": "SKYSEA Client View",
"versions": [
{
"status": "affected",
"version": "Ver.19.300.09h",
"versionType": "semver",
"lessThanOrEqual": "Ver.21.210.01f"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Sky Co., LTD.",
"product": "SKYMEC IT Manager",
"versions": [
{
"status": "affected",
"version": "Ver.2024.005.10a"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-08-25T07:17:10.600",
"references": [
{
"url": "https://jvn.jp/en/jp/JVN33423625/",
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://www.skyseaclientview.net/news/260824_01/",
"source": "vultures@jpcert.or.jp"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"description": [
{
"lang": "en",
"value": "CWE-25"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SKYSEA Client View and SKYMEC IT Manager contain a path traversal vulnerability. If this vulnerability is exploited, an attacker who can log in to a Windows system on which the affected product is installed may be able to execute arbitrary code on another Windows system that has the affected products installed and can receive UDP packets from that system. Note that this vulnerability is due to an incomplete fix for CVE-2024-41726."
}
],
"lastModified": "2026-08-28T16:09:10.947",
"sourceIdentifier": "vultures@jpcert.or.jp"
}