CVE-2026-59701
A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.15%
- Percentil entre todas las CVEs puntuadas: 4
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 %
AV:L + UI:P (interacción del usuario) indica explotación en cliente al abrir BMP preparado. OOB read en parser permite ejecución de código en el proceso (T1059).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-59701",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-59701",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-08-11T13:54:03.462849Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.3,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Simcenter Femap",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2606.0001",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-08-11T13:19:00.763",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-584312.html",
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
}
],
"lastModified": "2026-08-28T19:03:37.837",
"sourceIdentifier": "productcert@siemens.com"
}