CVE-2026-59296
Estado: Pendiente de análisisMedia (5.9)—
Using untrusted, non-normalized input as-is for metrics data (such as metric names, tag keys, or tag values) is a dangerous antipattern that general-purpose instrumentation should never perform. Micrometer 1.17.0 Micrometer 1.16.0 - 1.16.6 Micrometer 1.15.0 - 1.15.12 Micrometer 1.14.0 - 1.14.16 Micrometer 1.9.18 and earlier
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
- Puntuación base: 5.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.30%
- Percentil entre todas las CVEs puntuadas: 21
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-74
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-59296",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-59296",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-08-21T11:55:29.457945Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security@vmware.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "security@vmware.com",
"affectedData": [
{
"vendor": "Spring",
"product": "Micrometer",
"versions": [
{
"status": "affected",
"version": "1.17.0",
"versionType": "custom"
},
{
"status": "affected",
"version": "1.16.0",
"versionType": "custom",
"lessThanOrEqual": "1.16.6"
},
{
"status": "affected",
"version": "1.15.0",
"versionType": "custom",
"lessThanOrEqual": "1.15.12"
},
{
"status": "affected",
"version": "1.14.0",
"versionType": "custom",
"lessThanOrEqual": "1.14.16"
},
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.9.18"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-08-21T11:17:05.780",
"references": [
{
"url": "https://spring.io/security/cve-2026-59296",
"source": "security@vmware.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-74"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Using untrusted, non-normalized input as-is for metrics data (such as metric names, tag keys, or tag values) is a dangerous antipattern that general-purpose instrumentation should never perform.\nMicrometer 1.17.0\nMicrometer 1.16.0 - 1.16.6\nMicrometer 1.15.0 - 1.15.12\nMicrometer 1.14.0 - 1.14.16\nMicrometer 1.9.18 and earlier"
}
],
"lastModified": "2026-08-28T18:47:30.163",
"sourceIdentifier": "security@vmware.com"
}