CVE-2026-5703
Path traversal vulnerability in the Satel Iberia SenNet Datalogger Serie 200, specifically in the web portal provided by the device, which allows an authenticated user to read any file or list any directory accessible to the system user running the web server. This is possible by modifying the URL to include a path traversal payload. Successful exploitation of this vulnerability could allow an attacker to access critical system files containing confidential information.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.29%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1005Data from Local Systemcollection85 % - Impacto secundario
T1552Unsecured Credentialscredential access70 %
Vector AV:N con PR:L (red, autenticado) se mapea a T1210. El path traversal permite leer archivos del sistema (T1005) y acceder a información confidencial (T1552).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-35
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-5703",
"cveTags": [],
"metrics": {
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cve-coordination@incibe.es",
"affectedData": [
{
"vendor": "Satel Iberia",
"product": "SenNet Datalogger Serie 200",
"versions": [
{
"status": "affected",
"version": "V7.0m-1.53h"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-10-07T09:17:05.673",
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/path-traversal-satel-iberia-sennet-datalogger-serie-200",
"source": "cve-coordination@incibe.es"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Primary",
"source": "cve-coordination@incibe.es",
"description": [
{
"lang": "en",
"value": "CWE-35"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Path traversal vulnerability in the Satel Iberia SenNet Datalogger Serie 200, specifically in the web portal provided by the device, which allows an authenticated user to read any file or list any directory accessible to the system user running the web server. This is possible by modifying the URL to include a path traversal payload. Successful exploitation of this vulnerability could allow an attacker to access critical system files containing confidential information."
}
],
"lastModified": "2026-10-07T14:47:35.590",
"sourceIdentifier": "cve-coordination@incibe.es"
}