CVE-2026-5397

Estado: Pendiente de análisisAlta (7.8)—

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.

If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:L, PR:L sin UI permite escalada local. CWE-427 + DLL en directorio = DLL Hijacking (T1574.007). Ejecución con privilegios de administrador tras startup del servicio (T1059).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-5397",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-5397",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-04-15T13:46:38.260570Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.1
      }
    ]
  },
  "affected": [
    {
      "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
      "affectedData": [
        {
          "vendor": "OMRON SOCIAL SOLUTIONS CO., Ltd.",
          "product": "PowerAttendant Standard Edition",
          "versions": [
            {
              "status": "affected",
              "version": "2.1.2 or lower",
              "versionType": "custom"
            }
          ],
          "platforms": [
            "Windows"
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-04-15T05:16:45.740",
  "references": [
    {
      "url": "https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf",
      "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1"
    },
    {
      "url": "https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf",
      "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.\n\nIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup."
    }
  ],
  "lastModified": "2026-06-17T10:58:57.633",
  "sourceIdentifier": "bba440f9-ef23-4224-aa62-7ac0935d18d1"
}