CVE-2026-4827
CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.43%
- Percentil entre todas las CVEs puntuadas: 35
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution75 % - Impacto principal
T1078Valid Accountsstealth · persistence · privilege escalation · initial access65 %
UI:R con AV:N sugiere interacción del usuario (T1203). CWE-331 (insuficiente entropía) en gestión de sesiones permite acceso no autorizado, impactando en T1078 (obtención de credenciales/cuentas).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
CWE
- CWE-331
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-4827",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-4827",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-05-12T12:39:02.210471Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.7,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Easergy MiCOM C264",
"versions": [
{
"status": "affected",
"version": "Versions D6.x"
},
{
"status": "affected",
"version": "Versions D7.33 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Easergy C5",
"versions": [
{
"status": "affected",
"version": "Version 1.1.17 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Easergy MiCOM P30",
"versions": [
{
"status": "affected",
"version": "P139 version prior to P139.678.700"
},
{
"status": "affected",
"version": "P437 version prior to P437.678.700"
},
{
"status": "affected",
"version": "P439 version prior to P439.678.700"
},
{
"status": "affected",
"version": "P532 version prior to P532.678.700"
},
{
"status": "affected",
"version": "P539 version prior to P539.678.700"
},
{
"status": "affected",
"version": "P631 version prior to P631.678.700"
},
{
"status": "affected",
"version": "P632 version prior to P632.678.700"
},
{
"status": "affected",
"version": "P633 version prior to P633.678.700"
},
{
"status": "affected",
"version": "P634 version prior to P634.678.700"
},
{
"status": "affected",
"version": "P633 version P633.680.700 only"
},
{
"status": "affected",
"version": "P634 version P634.680.700 only"
},
{
"status": "affected",
"version": "P138 version prior to P138.677.700"
},
{
"status": "affected",
"version": "P436 version prior to P436.677.701"
},
{
"status": "affected",
"version": "P438 version prior to P438.677.701"
},
{
"status": "affected",
"version": "P638 version prior to P638.677.700"
},
{
"status": "affected",
"version": "C434 version prior to C434.679.700"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Easergy MiCOM P40",
"versions": [
{
"status": "affected",
"version": "Series model numbers with Protocol Option bit as G, H or L and all firmware versions"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "EcoStruxure™ Power Automation System Gateway (EPAS-GTW)",
"versions": [
{
"status": "affected",
"version": "Version 6.4.616.200.100 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "EcoStruxure™ Power Automation System User Interface (EPAS-UI)",
"versions": [
{
"status": "affected",
"version": "Version 3.0.3 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "EcoStruxure™ Power Operation",
"versions": [
{
"status": "affected",
"version": "Version 2022 CU6 and prior"
},
{
"status": "affected",
"version": "Version 2024 CU2 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "iPMFLS",
"versions": [
{
"status": "affected",
"version": "Version 64.2025.0.13 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "PowerLogic™ P5 Protection Relay",
"versions": [
{
"status": "affected",
"version": "V02.502.103 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "PowerLogic™ P7 Protection and Control Platform",
"versions": [
{
"status": "affected",
"version": "V02.002.002 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "PowerLogic™ T300",
"versions": [
{
"status": "affected",
"version": "Version 2.9.4 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "PowerLogic™ T500",
"versions": [
{
"status": "affected",
"version": "Version 11.08.02 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Saitel DP",
"versions": [
{
"status": "affected",
"version": "Version 11.06.36 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "EasyLogic T150 (formerly Saitel DR)",
"versions": [
{
"status": "affected",
"version": "Version 11.06.30 and prior"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-05-12T13:17:35.510",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-02.pdf",
"source": "cybersecurity@se.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-331"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections."
}
],
"lastModified": "2026-06-17T10:57:17.890",
"sourceIdentifier": "cybersecurity@se.com"
}