CVE-2026-3716
A vulnerability was determined in Wavlink WL-WN579X3-C 231124. This vulnerability affects the function sub_401AD4 of the file /cgi-bin/adm.cgi. Executing a manipulation of the argument Hostname can lead to cross site scripting. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 20260226 is able to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 1.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.37%
- Percentil entre todas las CVEs puntuadas: 29
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-79, CWE-94
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-3716",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-3716",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-03-11T13:49:54.813531Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 3.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N",
"authentication": "MULTIPLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.4,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 2.4,
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 0.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 1.7
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 1.9,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "PROOF_OF_CONCEPT",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Wavlink",
"product": "WL-WN579X3-C",
"versions": [
{
"status": "affected",
"version": "231124"
},
{
"status": "unaffected",
"version": "20260226"
}
]
}
]
}
],
"published": "2026-03-08T08:15:59.470",
"references": [
{
"url": "https://dl.wavlink.com/firmware/RD/WN579X3C_WAVLINK_V20260226_WO_cb3003b2.bin",
"tags": [
"Broken Link"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/Litengzheng/vul_db/blob/main/WL-WN579X3-C/vul_18/README.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.349661",
"tags": [
"Permissions Required",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.349661",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.765326",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
},
{
"lang": "en",
"value": "CWE-94"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Wavlink WL-WN579X3-C 231124. This vulnerability affects the function sub_401AD4 of the file /cgi-bin/adm.cgi. Executing a manipulation of the argument Hostname can lead to cross site scripting. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 20260226 is able to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product."
},
{
"lang": "es",
"value": "Se determinó una vulnerabilidad en Wavlink WL-WN579X3-C 231124. Esta vulnerabilidad afecta la función sub_401AD4 del archivo /cgi-bin/adm.cgi. La ejecución de una manipulación del argumento Hostname puede llevar a cross site scripting. Es posible lanzar el ataque remotamente. El exploit ha sido divulgado públicamente y puede ser utilizado. Actualizar a la versión 20260226 puede resolver este problema. El componente afectado debe ser actualizado. El proveedor se contactó tempranamente, respondió de manera muy profesional y rápidamente lanzó una versión corregida del producto afectado."
}
],
"lastModified": "2026-06-17T10:44:03.973",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:wavlink:wl-wn579x3-c_firmware:231124:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7671CD24-8B40-4B35-B1DC-0B863E707F28"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:wavlink:wl-wn579x3-c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "824705E8-A90D-4055-A3A1-9FAAD0458D75"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}