CVE-2026-3559
Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.39%
- Percentil entre todas las CVEs puntuadas: 31
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1078Valid Accountsstealth · persistence · privilege escalation · initial access75 % - Impacto secundario
T1098.004SSH Authorized Keyspersistence · privilege escalation60 %
Red adyacente (AV:A) sin privilegios (PR:N) contra servicio remoto (puerto 8080). Bypass de autenticación vía nonce estático permite acceso no autorizado a cuenta HomeKit o manipulación de dispositivo.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-323
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-3559",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-3559",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-03-16T20:19:38.659046Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.1,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "Philips",
"product": "Hue Bridge",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-03-16T14:19:51.820",
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-157/",
"tags": [
"Third Party Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-323"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451."
},
{
"lang": "es",
"value": "Vulnerabilidad de omisión de autenticación por nonce estático en el Protocolo de Accesorios HomeKit de Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red omitir la autenticación en instalaciones afectadas de Philips Hue Bridge. La autenticación no es necesaria para explotar esta vulnerabilidad.\n\nLa falla específica reside en la configuración del mecanismo de autenticación SRP en el servicio del Protocolo de Accesorios HomeKit, que escucha en el puerto TCP 8080 por defecto. El problema se debe al uso de un valor nonce estático. Un atacante puede aprovechar esta vulnerabilidad para omitir la autenticación en el sistema. Fue ZDI-CAN-28451."
}
],
"lastModified": "2026-06-17T10:43:47.230",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C4C925A5-D9FB-482D-A98D-F879B1BD21EC",
"versionEndExcluding": "1975170000"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "55B37D18-3A59-423E-9D73-F80DFDB14C4D"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}