« Volver al listado

CVE-2026-18849

Estado: AnalizadaMedia (6.8)—

IBM OpenBMC FW1060.00 through FW1060.80 is affected by a vulnerability in the BMC firmware update process. An attacker with authenticated administrator-level access to the BMC can, under specific conditions, execute arbitrary code, resulting in a confidentiality, integrity, and availability impact.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (9)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-18849",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-18849",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-08-21T16:09:43.502126Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "psirt@us.ibm.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.8,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@us.ibm.com",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:ibm:openbmc:fw1060.00:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:openbmc:fw1060.80:*:*:*:*:*:*:*"
          ],
          "vendor": "IBM",
          "product": "OPENBMC",
          "versions": [
            {
              "status": "affected",
              "version": "FW1060.00",
              "versionType": "semver",
              "lessThanOrEqual": "FW1060.80"
            }
          ]
        }
      ]
    }
  ],
  "published": "2026-08-19T21:16:54.663",
  "references": [
    {
      "url": "https://www.ibm.com/support/pages/node/7283590",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "psirt@us.ibm.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@us.ibm.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "IBM OpenBMC FW1060.00 through FW1060.80 is affected by a vulnerability in the BMC firmware update process. An attacker with authenticated administrator-level access to the BMC can, under specific conditions, execute arbitrary code, resulting in a confidentiality, integrity, and availability impact."
    }
  ],
  "lastModified": "2026-09-02T18:58:30.013",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:openbmc:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4E4898E2-7516-4F81-92C7-31B8EC891178",
              "versionEndIncluding": "fw1060.80",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:power_system_e1050_\\(9043-mrx\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2F04E3C9-94C6-42B0-9FBD-4AC5FEF42A1F",
              "versionEndExcluding": "fw1060.81",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ibm:power_system_e1050_\\(9043-mrx\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "061D193E-84BC-4DE7-96C4-B75D11769ED5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:power_system_l1022_\\(9786-22h\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EEBFE6F7-E6D8-47AC-B011-751FB9BC3D50",
              "versionEndExcluding": "fw1060.81",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ibm:power_system_l1022_\\(9786-22h\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B2C09090-C18F-464A-8DEF-E23B5990E2A4"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:power_system_l1024_\\(9786-42h\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D6EA818B-DC65-4F2D-9FC9-C610FFABE3DD",
              "versionEndExcluding": "fw1060.81",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ibm:power_system_l1024_\\(9786-42h\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "0170400B-89A7-4B44-9AA7-9A168C9CAE9C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:power_system_s1012_\\(9028-21b\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0524365D-8379-4B10-B9C5-FF80EE84BA27",
              "versionEndExcluding": "fw1060.81",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ibm:power_system_s1012_\\(9028-21b\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7BED85F2-8CCB-417C-A739-23828966A036"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:power_system_s1014_\\(9105-41b\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "41572D5A-C3A2-4294-9AF9-D4824675B4A3",
              "versionEndExcluding": "fw1060.81",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ibm:power_system_s1014_\\(9105-41b\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "ECD54B80-5754-4C19-AE0C-F539DEF96DCB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:power_system_s1022_\\(9105-22a\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0BB54554-C9DC-4072-A205-EA9DD4E15688",
              "versionEndExcluding": "fw1060.81",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ibm:power_system_s1022_\\(9105-22a\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E3E15C41-9CBD-4F66-A176-07B3E9BBD81D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:power_system_s1022s_\\(9105-22b\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "51C2576F-E4DD-4002-9E41-CF89F92E2064",
              "versionEndExcluding": "fw1060.81",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ibm:power_system_s1022s_\\(9105-22b\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "564A665A-7B94-40CE-A4D9-CDD0CCF52B2E"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ibm:power_system_s1024_\\(9105-42a\\)_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FA4B835D-CEAB-422B-9F38-F63AF84396C3",
              "versionEndExcluding": "fw1060.81",
              "versionStartIncluding": "fw1060.00"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ibm:power_system_s1024_\\(9105-42a\\):-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E49EE658-B8AE-48F7-A765-92BA3A630AA0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "psirt@us.ibm.com"
}