CVE-2026-12686
An authenticated user could manipulate a company ID parameter in a POST request to the backend to gain unauthorised access to other companies hosted within the same subdomain environment. The application does not adequately verify whether the requested company ID belongs to the authenticated user’s session, resulting in a cross-tenant authorisation bypass. If this vulnerability is successfully exploited, it allows unauthorised access to sensitive customer information, including billing data, and may enable the unauthorised modification of third-party data.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:H/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 9.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.37%
- Percentil entre todas las CVEs puntuadas: 29
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1078.002Domain Accountsstealth · persistence · privilege escalation · initial access80 % - Impacto secundario
T1005Data from Local Systemcollection75 % - Impacto secundario
T1565.001Stored Data Manipulationimpact70 %
Vulnerabilidad de autorización insuficiente (CWE-639) que requiere autenticación previa (PR:L) para manipular parámetro de empresa en POST; acceso a datos sensibles de otros clientes e impacto en confidencialidad (VC:H) e integridad (VI:H).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
CWE
- CWE-639
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-12686",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-12686",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-07-06T12:50:50.832426Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:H/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cve-coordination@incibe.es",
"affectedData": [
{
"vendor": "Adiss",
"product": "Biloop",
"versions": [
{
"status": "affected",
"version": "6.1.1"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-07-06T11:16:26.797",
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/incorrect-authorisation-adisss-biloop",
"source": "cve-coordination@incibe.es"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"description": [
{
"lang": "en",
"value": "CWE-639"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An authenticated user could manipulate a company ID parameter in a POST request to the backend to gain unauthorised access to other companies hosted within the same subdomain environment. The application does not adequately verify whether the requested company ID belongs to the authenticated user’s session, resulting in a cross-tenant authorisation bypass. If this vulnerability is successfully exploited, it allows unauthorised access to sensitive customer information, including billing data, and may enable the unauthorised modification of third-party data."
}
],
"lastModified": "2026-07-06T18:41:46.210",
"sourceIdentifier": "cve-coordination@incibe.es"
}