« Volver al listado

CVE-2026-10164

Estado: AplazadaAlta (7.4)—

A vulnerability was found in Edimax BR-6478AC 1.23. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request Handler. The manipulation of the argument ShareName/SelectName results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Buffer overflow en servicio web remoto (POST /goform/formUSBFolder) que requiere autenticación (PR:L), permitiendo ejecución de código. CWE-119/120 confirman desbordamiento. El router Edimax expuesto en red interna o con credenciales comprometidas es accesible remotamente.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-10164",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-10164",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-06-02T02:19:08.337545Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "authentication": "SINGLE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 7.4,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cna@vuldb.com",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:edimax:br-6478ac_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "Edimax",
          "modules": [
            "POST Request Handler"
          ],
          "product": "BR-6478AC",
          "versions": [
            {
              "status": "affected",
              "version": "1.23"
            }
          ]
        }
      ]
    }
  ],
  "published": "2026-05-31T04:16:19.333",
  "references": [
    {
      "url": "https://lavender-bicycle-a5a.notion.site/EDIMAX-BR6478ACV2-formUSBFolder-34b53a41781f80559b15f262ba914d57?source=copy_link",
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/submit/818600",
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/vuln/367417",
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/vuln/367417/cti",
      "source": "cna@vuldb.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cna@vuldb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        },
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Edimax BR-6478AC 1.23. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request Handler. The manipulation of the argument ShareName/SelectName results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en Edimax BR-6478AC 1.23. Afectada es la función formUSBFolder del archivo /goform/formUSBFolder del componente Gestor de Solicitudes POST. La manipulación del argumento ShareName/SelectName resulta en desbordamiento de búfer. El ataque puede ser ejecutado remotamente. El exploit ha sido hecho público y podría ser usado."
    }
  ],
  "lastModified": "2026-07-22T07:10:00.107",
  "sourceIdentifier": "cna@vuldb.com"
}