CVE-2025-9495
The Vitogate 300 web interface fails to enforce proper server-side authentication and relies on frontend-based authentication controls. This allows an attacker to simply modify HTML elements in the browser’s developer tools to bypass login restrictions. By removing specific UI elements, an attacker can reveal the hidden administration menu, giving them full control over the device.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.24%
- Percentil entre todas las CVEs puntuadas: 14
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access85 % - Impacto secundario
T1098.001Additional Cloud Credentialspersistence · privilege escalation70 % - Impacto secundario
T1565.001Stored Data Manipulationimpact65 %
AV:A sin PR indica red adyacente; fallo de autenticación servidor permite acceso con permisos administrativos y manipulación de configuración del dispositivo.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-602
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-9495",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-9495",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-09-23T13:33:41.544746Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productsecurity@carrier.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.7,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productsecurity@carrier.com",
"affectedData": [
{
"vendor": "Viessmann",
"product": "Vitogate 300",
"versions": [
{
"status": "affected",
"version": "1",
"lessThan": "3.0.0.0",
"versionType": "date"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-09-23T02:15:47.563",
"references": [
{
"url": "https://https://www.corporate.carrier.com/product-security/advisories-resources/",
"source": "productsecurity@carrier.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productsecurity@carrier.com",
"description": [
{
"lang": "en",
"value": "CWE-602"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Vitogate 300 web interface fails to enforce proper server-side authentication and relies on frontend-based authentication controls. This allows an attacker to simply modify HTML elements in the browser’s developer tools to bypass login restrictions. By removing specific UI elements, an attacker can reveal the hidden administration menu, giving them full control over the device."
}
],
"lastModified": "2026-06-17T10:09:06.587",
"sourceIdentifier": "productsecurity@carrier.com"
}