CVE-2025-9253
A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function RP_doSpecifySiteSurvey of the file /goform/RP_doSpecifySiteSurvey. The manipulation of the argument ssidhex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.96%
- Percentil entre todas las CVEs puntuadas: 60
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1059Command and Scripting Interpreterexecution80 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation75 %
Buffer overflow en servicio remoto (PR:L requiere privilegios de red adyacente) permite ejecución de código arbitrario. Vector CVSS AV:N/PR:L/VI:H/VC:H indica acceso remoto con credenciales y máximo impacto en integridad/confidencialidad.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (6)
CWE
- CWE-119, CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-9253",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-9253",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-08-21T13:24:41.746941Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.4,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "PROOF_OF_CONCEPT",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Linksys",
"product": "RE6250",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE6300",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE6350",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE6500",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE7000",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE9000",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
}
]
}
],
"published": "2025-08-20T23:15:30.037",
"references": [
{
"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_22/22.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.320784",
"tags": [
"Permissions Required"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.320784",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.631526",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://www.linksys.com/",
"tags": [
"Product"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_22/22.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-119"
},
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function RP_doSpecifySiteSurvey of the file /goform/RP_doSpecifySiteSurvey. The manipulation of the argument ssidhex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad de seguridad en los Linksys RE6250, RE6300, RE6350, RE6500, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. La función RP_doSpecifySiteSurvey del archivo /goform/RP_doSpecifySiteSurvey se ve afectada. La manipulación del argumento ssidhex provoca un desbordamiento del búfer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho público el exploit y puede que sea utilizado. Se contactó al proveedor con antelación para informarle sobre esta divulgación, pero no respondió."
}
],
"lastModified": "2026-06-17T10:08:37.513",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}