« Volver al listado

CVE-2025-5965

Estado: AnalizadaAlta (7.2)—

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:N/PR:H indica acceso remoto con privilegios altos (administrador); CWE-78 es inyección de comandos OS; el atacante concatena instrucciones a la configuración de backup para ejecutar comandos arbitrarios.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-5965",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-5965",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-01-05T20:01:00.415596Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
      "affectedData": [
        {
          "vendor": "Centreon",
          "modules": [
            "Backup configuration in the administration setup"
          ],
          "product": "Infra Monitoring",
          "versions": [
            {
              "status": "affected",
              "version": "25.10.0",
              "lessThan": "25.10.2",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "24.10.0",
              "lessThan": "24.10.15",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "24.04.0",
              "lessThan": "24.04.19",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-01-05T10:15:55.870",
  "references": [
    {
      "url": "https://github.com/centreon/centreon/releases",
      "tags": [
        "Release Notes"
      ],
      "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
    },
    {
      "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."
    },
    {
      "lang": "es",
      "value": "En los parámetros de copia de seguridad, un usuario con altos privilegios puede concatenar instrucciones personalizadas a la configuración de la copia de seguridad. Una vulnerabilidad de neutralización incorrecta de elementos especiales utilizados en un comando del sistema operativo ('inyección de comandos del sistema operativo') en Centreon Infra Monitoring (configuración de copia de seguridad en los módulos de configuración de administración) permite la inyección de comandos del sistema operativo. Este problema afecta a Infra Monitoring: de 25.10.0 anterior a 25.10.2, de 24.10.0 anterior a 24.10.15, de 24.04.0 anterior a 24.04.19."
    }
  ],
  "lastModified": "2026-09-30T23:10:00.237",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "440A575D-6C68-4894-A4DB-C62065FE0349",
              "versionEndExcluding": "24.04.19",
              "versionStartIncluding": "24.04.0"
            },
            {
              "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BE9F2C39-E778-4EFE-8E0B-14D5174A717D",
              "versionEndExcluding": "24.10.15",
              "versionStartIncluding": "24.10.0"
            },
            {
              "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1842C772-1AC5-49B3-A209-2B8AD6C31134",
              "versionEndExcluding": "25.10.2",
              "versionStartIncluding": "25.10.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
}