CVE-2025-59092
An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.88%
- Percentil entre todas las CVEs puntuadas: 58
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1565.002Transmitted Data Manipulationimpact80 % - Impacto secundario
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access70 %
Servicio RPC en puerto 4000 sin autenticación (AV:N/PR:N/UI:N) permite manipular datos de estado del sistema de control de acceso (CWE-798: credenciales hardcodeadas/ausentes), impactando integridad (VI:H) mediante envío de información falsa sobre contactos de puertas.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-798
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-59092",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-59092",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-01-26T17:25:14.060276Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.7,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"affectedData": [
{
"vendor": "dormakaba",
"product": "Kaba exos 9300",
"versions": [
{
"status": "affected",
"version": "< 4.4.0"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-01-26T10:16:06.590",
"references": [
{
"url": "https://r.sec-consult.com/dkexos",
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
},
{
"url": "https://r.sec-consult.com/dormakaba",
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
},
{
"url": "https://www.dormakabagroup.com/en/security-advisories",
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication."
},
{
"lang": "es",
"value": "Un servicio RPC, que forma parte de exos 9300, es accesible en el puerto 4000, ejecutado por el proceso FSMobilePhoneInterface.exe. Este servicio se utiliza para la comunicación entre procesos entre servicios y la GUI de Kaba exos 9300, conteniendo información de estado sobre los Gestores de Acceso. La interacción con el servicio no requiere ninguna autenticación. Por lo tanto, es posible enviar información de estado arbitraria sobre contactos de puerta, etc., sin autenticación previa."
}
],
"lastModified": "2026-06-17T09:45:32.223",
"sourceIdentifier": "551230f0-3615-47bd-b7cc-93e92e730bbf"
}