CVE-2025-5825
Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.
The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.28%
- Percentil entre todas las CVEs puntuadas: 19
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1059Command and Scripting Interpreterexecution80 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation70 %
AV:A (red adyacente) con T1210. Explotación mediante emparejamiento Bluetooth malicioso del proceso de actualización sin validación. Ejecución arbitraria de código (T1059) y potencial escalada de privilegios en el dispositivo (T1068).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (9)
CWE
- CWE-1328
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-5825",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-5825",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-06-25T18:17:50.082273Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "Autel",
"product": "Autel MaxiCharger AC Wallbox Commercial",
"versions": [
{
"status": "affected",
"version": "1.36.00"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-06-25T18:15:23.303",
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-25-344/",
"tags": [
"Third Party Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-1328"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354."
},
{
"lang": "es",
"value": "Vulnerabilidad de ejecución remota de código en la degradación del firmware de Autel MaxiCharger AC Wallbox Commercial. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en las instalaciones afectadas de las estaciones de carga Autel MaxiCharger AC Wallbox Commercial. Para explotar esta vulnerabilidad, un atacante debe primero vincular un dispositivo Bluetooth malicioso con el sistema objetivo. La falla específica se encuentra en el proceso de actualización del firmware. El problema se debe a la falta de validación adecuada de una imagen de firmware antes de usarla para realizar una actualización. Un atacante puede aprovechar esto, junto con otras vulnerabilidades, para ejecutar código arbitrario en el dispositivo. Anteriormente, se denominaba ZDI-CAN-26354."
}
],
"lastModified": "2026-06-17T09:48:49.260",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "0C17A950-221C-41E3-9BE3-31736CE4516F",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "42F0DDFA-A1B9-4EC2-8F43-3261F9BCE814",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_elite_business_c50:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5B2F9001-71B7-4B39-9114-FC54F4EAE9E7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_pro_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "9471EA48-BD48-40AA-8FF7-28503D04D1F0",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_pro_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "72FB45A6-E876-45A6-A39F-4E0B28620A71",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_pro:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "92CF3B40-B18F-4C4D-8A6C-68A8B1F288AE"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_ultra_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "55C717AF-39F9-4080-AE56-7511E0F62F79",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_ultra_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "7AFD91E7-E581-451B-AB15-099AA7A4F611",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_ultra:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CDC6E5EB-C4D4-4488-B01B-C0E568FCA0D1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_mobile_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "2C9AEB54-FFBC-4B24-AC7B-1B5F3CC762DF",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_mobile_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "BBFCD8D0-53E7-4B06-B763-36381E13DD26",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_compact_mobile:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "52578631-C18D-4244-9377-AB787EDE08A1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_pedestal_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "FED7B2BF-5D38-4393-9986-588407A3476D",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_pedestal_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "3244FD64-1714-4597-BA66-CC5FC8D514FF",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_compact_pedestal:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "ED75BBD9-D889-49D3-95B0-EF6F15B65E10"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_fast_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "264E7F9D-0603-43C9-B7A9-6A35EA8F0063",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_fast_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "E5F4FE58-5AA6-45D0-AE48-959DA0CF53C8",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_fast:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6C8B42B3-3F66-426F-8FFE-993FCAA12EB4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_hipower_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "E30E7592-29C4-4333-A02C-7468074BD104",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_hipower_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "F9058C73-831E-48BF-AE9B-19AB33F10F14",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_hipower:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EE5DF603-DBD2-4AFF-AE3D-946277C2C6C2"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dh480_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "33F4A529-54C4-4EBC-871E-5E0C71859F69",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dh480_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "62718E33-B591-49D4-8CC6-057D6254873A",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dh480:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CAD62E93-8613-48DF-9C42-B12655FE1680"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_single_charger_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "372D3478-67AA-4D41-908C-5CFE6CAA25A8",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_single_charger_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "8ED07235-5610-4E80-8940-6EB942CC648C",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_single_charger:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0E6B2074-D4A6-424F-B7C5-40A0FE5C17F8"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}