CVE-2025-57602
Insufficient hardening of the proxyuser account in the AiKaan IoT management platform, combined with the use of a shared, hardcoded SSH private key, allows remote attackers to authenticate to the cloud controller, gain interactive shell access, and pivot into other connected IoT devices. This can lead to remote code execution, information disclosure, and privilege escalation across customer environments.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.53%
- Percentil entre todas las CVEs puntuadas: 43
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access90 % - Impacto secundario
T1059Command and Scripting Interpreterexecution85 % - Impacto secundario
T1570Lateral Tool Transferlateral movement75 %
Credencial hardcodeada (CWE-798) en aplicación expuesta (AV:N, PR:N, UI:N) permite autenticación remota SSH y pivoteo lateral a dispositivos IoT con ejecución de comandos remota.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-798
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-57602",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-57602",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-09-23T16:05:53.979000Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2025-09-22T16:15:45.130",
"references": [
{
"url": "https://github.com/Shubhangborkar/aikaan-vulnerabilities/blob/main/cve2-proxyuser-shell.md",
"source": "cve@mitre.org"
},
{
"url": "https://github.com/Shubhangborkar/aikaan-vulnerabilities/blob/main/cve2-proxyuser-shell.md",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient hardening of the proxyuser account in the AiKaan IoT management platform, combined with the use of a shared, hardcoded SSH private key, allows remote attackers to authenticate to the cloud controller, gain interactive shell access, and pivot into other connected IoT devices. This can lead to remote code execution, information disclosure, and privilege escalation across customer environments."
}
],
"lastModified": "2026-06-17T09:43:13.593",
"sourceIdentifier": "cve@mitre.org"
}