« Volver al listado

CVE-2025-5741

Estado: AplazadaMedia (6.9)—

CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file reads from the charging station. The exploitation of this vulnerability does require an authenticated session of the web server.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-5741",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-5741",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-06-10T13:08:40.755797Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.2
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 6.9,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "EVLink WallBox",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-06-10T09:15:25.290",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-161-03.pdf",
      "source": "cybersecurity@se.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that\ncould cause arbitrary file reads from the charging station. The exploitation of this vulnerability does require an\nauthenticated session of the web server."
    },
    {
      "lang": "es",
      "value": "CWE-22: Existe una vulnerabilidad de limitación incorrecta de una ruta a un directorio restringido («Path Traversal») que podría provocar lecturas arbitrarias de archivos desde la estación de carga. Para explotar esta vulnerabilidad se requiere una sesión autenticada del servidor web."
    }
  ],
  "lastModified": "2026-06-17T09:48:40.263",
  "sourceIdentifier": "cybersecurity@se.com"
}