CVE-2025-5444
A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 14%
- Percentil entre todas las CVEs puntuadas: 96
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (6)
CWE
- CWE-77, CWE-78
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-5444",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-5444",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-06-02T16:27:49.243918Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Linksys",
"product": "RE6500",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE6250",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE6300",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE6350",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE7000",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"vendor": "Linksys",
"product": "RE9000",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
}
]
}
],
"published": "2025-06-02T12:15:26.337",
"references": [
{
"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.310783",
"tags": [
"Permissions Required"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.310783",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.584366",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://www.linksys.com/",
"tags": [
"Product"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_7/7.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-77"
},
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 (1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001), clasificada como crítica. Esta vulnerabilidad afecta a la función RP_UpgradeFWByBBS del archivo /goform/RP_UpgradeFWByBBS. La manipulación del argumento type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw provoca la inyección de comandos del sistema operativo. El ataque puede ejecutarse en remoto. Se ha hecho público el exploit y puede que sea utilizado. Se contactó al proveedor con antelación para informarle sobre esta divulgación, pero no respondió."
}
],
"lastModified": "2026-06-17T09:47:56.480",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}