CVE-2025-5023
Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.23%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access80 % - Impacto secundario
T1005Data from Local Systemcollection75 % - Impacto secundario
T1565.001Stored Data Manipulationimpact70 %
AV:A sin privilegios previos → T1210 (red adyacente). Credenciales hardcoded T1078.001. Acceso a datos de generación y venta (T1005). Capacidad de modificar/destruir información (T1565.001).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-798
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-5023",
"cveTags": [
{
"tags": [
"unsupported-when-assigned"
],
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}
],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-5023",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-07-10T14:03:35.221730Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.1,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 5.5,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"affectedData": [
{
"vendor": "Mitsubishi Electric Corporation",
"product": "PV-DR004J",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Mitsubishi Electric Corporation",
"product": "PV-DR004JA",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-07-10T09:15:30.623",
"references": [
{
"url": "https://jvn.jp/vu/JVNVU90283680/",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
},
{
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-007_en.pdf",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020."
},
{
"lang": "es",
"value": "La vulnerabilidad de uso de credenciales codificadas en el monitor del sistema fotovoltaico “EcoGuideTAB” de Mitsubishi Electric Corporation (PV-DR004J y PV-DR004JA en todas sus versiones) permite a un atacante dentro del rango de comunicación Wi-Fi entre las unidades del producto (unidad de medición y unidad de visualización) divulgar información, como la energía generada y la electricidad vendida a la red eléctrica, almacenada en el producto, manipular o destruir información almacenada o configurada en el producto, o provocar una denegación de servicio (DoS) en el producto mediante el uso de un ID de usuario y una contraseña codificados, comunes a la serie del producto, obtenidos mediante la explotación de CVE-2025-5022. Sin embargo, el producto no se ve afectado por esta vulnerabilidad si permanece sin uso durante un período determinado (predeterminado: 5 minutos) y entra en modo de ahorro de energía con la pantalla LCD de la unidad de visualización apagada. Los productos afectados se discontinuaron en 2015 y el soporte técnico finalizó en 2020."
}
],
"lastModified": "2026-06-17T09:47:02.840",
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}