CVE-2025-5022
Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID.
Leer descripción completaMostrar menos
In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.58%
- Percentil entre todas las CVEs puntuadas: 46
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-521
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-5022",
"cveTags": [
{
"tags": [
"unsupported-when-assigned"
],
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}
],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-5022",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-07-10T13:50:34.605783Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"affectedData": [
{
"vendor": "Mitsubishi Electric Corporation",
"product": "PV-DR004J",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Mitsubishi Electric Corporation",
"product": "PV-DR004JA",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-07-10T09:15:30.420",
"references": [
{
"url": "https://jvn.jp/vu/JVNVU90283680/",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
},
{
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-007_en.pdf",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"description": [
{
"lang": "en",
"value": "CWE-521"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020."
},
{
"lang": "es",
"value": "La vulnerabilidad de requisitos de contraseña débiles en el monitor del sistema fotovoltaico “EcoGuideTAB” de Mitsubishi Electric Corporation (PV-DR004J y PV-DR004JA en todas sus versiones) permite a un atacante, dentro del rango de comunicación Wi-Fi entre las unidades del producto (unidad de medición y unidad de visualización), obtener la contraseña del SSID. Sin embargo, el producto no se ve afectado por esta vulnerabilidad si permanece sin uso durante un periodo determinado (predeterminado: 5 minutos) y entra en modo de ahorro de energía con la pantalla LCD apagada. Los productos afectados se discontinuaron en 2015 y el soporte técnico finalizó en 2020."
}
],
"lastModified": "2026-06-17T09:47:02.730",
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}