CVE-2025-48709
Estado: AnalizadaMedia (4.8)—
BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 4.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.13%
- Percentil entre todas las CVEs puntuadas: 2
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-214, CWE-532
- CWE-522
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-48709",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "9119a7d8-5eab-497f-8521-727c672e3725",
"ssvcData": {
"id": "CVE-2025-48709",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-10-02T16:23:53.246063Z"
}
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-48709",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-10-27T15:23:04.978628Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "9119a7d8-5eab-497f-8521-727c672e3725",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 3.8,
"attackVector": "LOCAL",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "9119a7d8-5eab-497f-8521-727c672e3725",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 4.8,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "9119a7d8-5eab-497f-8521-727c672e3725",
"affectedData": [
{
"vendor": "BMC",
"product": "Control-M/Server",
"versions": [
{
"status": "affected",
"version": "9.0.21.300",
"lessThan": "PACTV.9.0.21.307",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "PACTV.9.0.21.307"
}
],
"defaultStatus": "affected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*"
],
"vendor": "bmc",
"product": "control-m",
"versions": [
{
"status": "affected",
"version": "9.0.21.300",
"lessThan": "9.0.21.300 PACTV.9.0.21.307",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "PACTV.9.0.21.307"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-08-07T20:15:28.117",
"references": [
{
"url": "https://docs.bmc.com/xwiki/bin/view/Control-M-Orchestration/Control-M/ctm9021/Patches/Control-M-Server-PACTV-9-0-21-307/",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "9119a7d8-5eab-497f-8521-727c672e3725"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "9119a7d8-5eab-497f-8521-727c672e3725",
"description": [
{
"lang": "en",
"value": "CWE-214"
},
{
"lang": "en",
"value": "CWE-532"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307."
},
{
"lang": "es",
"value": "Se detectó un problema en BMC Control-M 9.0.21.300. Cuando el servidor Control-M tiene una conexión a la base de datos, ejecuta DBUStatus.exe con frecuencia, lo que a su vez llama a dbu_connection_details.vbs con el nombre de usuario, la contraseña, el nombre de host de la base de datos y el puerto escritos en texto sin cifrar, lo cual se puede ver en los registros de eventos y procesos en dos ubicaciones distintas."
}
],
"lastModified": "2026-06-17T09:30:12.970",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bmc:control-m\\/server:9.0.21.300:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "912B4C5A-725E-4567-8A94-E58343B545CB"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "9119a7d8-5eab-497f-8521-727c672e3725"
}