CVE-2025-47419
Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 10
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.29%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access75 % - Impacto principal
T1552.001Credentials In Filescredential access85 % - Impacto secundario
T1040Network Sniffingcredential access · discovery80 %
AV:N/PR:N sin UI indica acceso remoto sin autenticación (T1190). CWE-319 y transmisión en claro de credenciales permite captura de contraseñas (T1552.001) mediante sniffing de tráfico (T1040).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-319
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-47419",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-47419",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-05-07T13:47:55.617300Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 10,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"affectedData": [
{
"vendor": "Crestron",
"product": "Automate VX",
"versions": [
{
"status": "affected",
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"version": "5.6.8161.21536",
"versionType": "custom",
"lessThanOrEqual": "6.4.0.49"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-05-06T21:16:20.867",
"references": [
{
"url": "https://security.crestron.com/",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3"
},
{
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3"
},
{
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.\n\nThe device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.\n\n\nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
},
{
"lang": "es",
"value": "La vulnerabilidad de transmisión de información confidencial en texto plano en Crestron Automate VX permite rastrear el tráfico de red. El dispositivo permite el acceso a la interfaz web y la API a través de puertos de red no seguros, lo que expone información confidencial, como las contraseñas de los usuarios. Este problema afecta a Automate VX desde la versión 5.6.8161.21536 hasta la 6.4.0.49."
}
],
"lastModified": "2026-06-17T09:28:05.537",
"sourceIdentifier": "25b0b659-c4b4-483f-aecb-067757d23ef3"
}