CVE-2025-46628
Lack of input validation/sanitization in the 'ate' management service in the Tenda RX2 Pro 16.03.30.14 allows an unauthorized remote attacker to gain root shell access to the device by sending a crafted UDP packet to the 'ate' service when it is enabled. Authentication is not needed.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.00%
- Percentil entre todas las CVEs puntuadas: 62
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1068Exploitation for Privilege Escalationprivilege escalation90 % - Impacto secundario
T1059Command and Scripting Interpreterexecution85 %
AV:N/PR:N/UI:N indica explotación remota sin autenticación (T1190). El atacante consigue acceso root shell, lo que implica escalada de privilegios (T1068) y ejecución de comandos (T1059) en el dispositivo comprometido.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-284
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-46628",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-46628",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-05-02T15:13:03.764709Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2025-05-01T20:15:38.510",
"references": [
{
"url": "https://blog.uturn.dev/#/writeups/iot-village/tenda-rx2pro/README?id=cve-2025-46628-command-injection-through-ifconfig-command-in-ate",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.tendacn.com/us/default.html",
"tags": [
"Product"
],
"source": "cve@mitre.org"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Lack of input validation/sanitization in the 'ate' management service in the Tenda RX2 Pro 16.03.30.14 allows an unauthorized remote attacker to gain root shell access to the device by sending a crafted UDP packet to the 'ate' service when it is enabled. Authentication is not needed."
},
{
"lang": "es",
"value": "La falta de validación/depuración de entrada en el servicio de gestión \"ate\" del Tenda RX2 Pro 16.03.30.14 permite que un atacante remoto no autorizado obtenga acceso root al dispositivo mediante el envío de un paquete UDP manipulado al servicio \"ate\" cuando este está habilitado. No se requiere autenticación."
}
],
"lastModified": "2026-06-17T09:26:44.150",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:rx2_pro_firmware:16.03.30.14:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A6C6559F-BD91-44DF-BA9E-2F55C714009C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:rx2_pro:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E95CB932-CDB6-4E44-A868-5DEEAD982F7C"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}