CVE-2025-43021
Estado: AnalizadaMedia (5.9)—
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the use and retrieval of the default password. HP has addressed the issue in the latest software update.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.15%
- Percentil entre todas las CVEs puntuadas: 4
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-1393
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-43021",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-43021",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-07-23T20:08:55.434389Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.7,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.1
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "hp-security-alert@hp.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.9,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "hp-security-alert@hp.com",
"affectedData": [
{
"vendor": "HP Inc.",
"product": "Poly Clariti Manager",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-07-22T23:15:24.687",
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037",
"tags": [
"Vendor Advisory"
],
"source": "hp-security-alert@hp.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "hp-security-alert@hp.com",
"description": [
{
"lang": "en",
"value": "CWE-1393"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the use and retrieval of the default password. HP has addressed the issue in the latest software update."
},
{
"lang": "es",
"value": "Se ha identificado una posible vulnerabilidad de seguridad en Poly Clariti Manager para versiones anteriores a la 10.12.1. Esta vulnerabilidad podría permitir el uso y la recuperación de la contraseña predeterminada. HP ha solucionado el problema en la última actualización de software."
}
],
"lastModified": "2026-06-17T09:23:25.250",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hp:poly_clariti_manager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "82C289E5-06F3-48F9-8C75-6CCFE4686F5C",
"versionEndExcluding": "10.12.2"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "hp-security-alert@hp.com"
}