CVE-2025-41771
Estado: Pendiente de análisisMedia (5.3)—
An authenticated attacker with low privileges can access an endpoint in the controller’s web interface that is vulnerable to SQL injection. The vulnerability affects a SQLite database used only for storing notification messages. Therefore, the impact is limited to the system’s notification functionality.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.27%
- Percentil entre todas las CVEs puntuadas: 18
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
CWE
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-41771",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-41771",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-08-12T12:31:57.783579Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "info@cert.vde.com",
"affectedData": [
{
"vendor": "Phoenix Contact",
"product": "AXC F 1152",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "AXC F 1252",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "AXC F 2000 EA",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "AXC F 2152",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "AXC F 3152",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "BPC 9102S",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "BPC 9202S",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "RFC 4072R",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "RFC 4072S",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "VL3 UPC 2440 EDGE",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "VPLCNEXT CONTROL 1000",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "VPLCNEXT CONTROL 2000",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "VPLCNEXT CONTROL 3000",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "VPLCNEXT CONTROL 500",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "Catan C1",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "EPC 1502",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Phoenix Contact",
"product": "EPC 1522",
"versions": [
{
"status": "affected",
"version": "2019.0.4",
"lessThan": "2026.0.3",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-08-12T08:17:12.130",
"references": [
{
"url": "https://phoenixcontact.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-056.json",
"source": "info@cert.vde.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An authenticated attacker with low privileges can access an endpoint in the controller’s web interface that is vulnerable to SQL injection. The vulnerability affects a SQLite database used only for storing notification messages. Therefore, the impact is limited to the system’s notification functionality."
},
{
"lang": "es",
"value": "Un atacante autenticado con privilegios bajos puede acceder a un endpoint en la interfaz web del controlador que es vulnerable a inyección SQL. La vulnerabilidad afecta una base de datos SQLite utilizada únicamente para almacenar mensajes de notificación. Por lo tanto, el impacto se limita a la funcionalidad de notificación del sistema."
}
],
"lastModified": "2026-09-29T11:10:00.150",
"sourceIdentifier": "info@cert.vde.com"
}