« Volver al listado

CVE-2025-41109

Estado: AnalizadaAlta (8.7)—

Ghost Robotics Vision 60 v0.27.2 includes, among its physical interfaces, three RJ45 connectors and a USB Type-C port. The vulnerability is due to the lack of authentication mechanisms when establishing connections through these ports. Specifically, with regard to network connectivity, the robot's internal router automatically assigns IP addresses to any device physically connected to it. An attacker could connect a WiFi access point under their control to gain access to the robot's network without needing the credentials for the deployed network. Once inside, the attacker can monitor all its data, as the robot runs on ROS 2 without authentication by default.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Acceso a red adyacente (AV:A) sin autenticación en puertos físicos RJ45. Una vez dentro, obtiene acceso a cuentas (credenciales por defecto en ROS 2) y monitoreo de datos del robot sin mecanismos de seguridad.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-41109",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-41109",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-10-22T15:49:41.124089Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.6,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 0.9
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cve-coordination@incibe.es",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 8.7,
          "Automatable": "NOT_DEFINED",
          "attackVector": "ADJACENT",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cve-coordination@incibe.es",
      "affectedData": [
        {
          "vendor": "Ghost Robotics",
          "product": "Vision 60",
          "versions": [
            {
              "status": "affected",
              "version": "0.27.2"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-10-22T09:15:36.617",
  "references": [
    {
      "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-ghost-robotics-vision-60",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve-coordination@incibe.es"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cve-coordination@incibe.es",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Ghost Robotics Vision 60 v0.27.2 includes, among its physical interfaces, three RJ45 connectors and a USB Type-C port. The vulnerability is due to the lack of authentication mechanisms when establishing connections through these ports. Specifically, with regard to network connectivity, the robot's internal router automatically assigns IP addresses to any device physically connected to it. An attacker could connect a WiFi access point under their control to gain access to the robot's network without needing the credentials for the deployed network. Once inside, the attacker can monitor all its data, as the robot runs on ROS 2 without authentication by default."
    }
  ],
  "lastModified": "2026-06-17T09:22:35.983",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ghostrobotics:vision_60_firmware:0.27.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6C0D9971-6E9B-4F72-B650-A3FD0B004507"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ghostrobotics:vision_60:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "5E213EE6-FF18-4C56-8CE0-50E140A650E3"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve-coordination@incibe.es"
}