CVE-2025-41108
The communication protocol implemented in Ghost Robotics Vision 60 v0.27.2 could allow an attacker to send commands to the robot from an external attack station, impersonating the control station (tablet) and gaining unauthorised full control of the robot. The absence of encryption and authentication mechanisms in the communication protocol allows an attacker to capture legitimate traffic between the robot and the controller, replicate it, and send any valid command to the robot from any attacking computer or device. The communication protocol used in this interface is based on MAVLink, a widely documented protocol, which increases the likelihood of attack. There are two methods for connecting to the robot remotely: Wi-Fi and 4G/LTE.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 9.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.31%
- Percentil entre todas las CVEs puntuadas: 22
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1078Valid Accountsstealth · persistence · privilege escalation · initial access80 % - Impacto secundario
T1059Command and Scripting Interpreterexecution75 %
AV:N sin autenticación (CWE-287) permite enviar comandos al robot desde red externa. Control total sin cifrado/auth equivale a suplantación de identidad (T1078) y ejecución remota de comandos (T1059).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-287
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-41108",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-41108",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-10-22T15:49:11.427452Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.2,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cve-coordination@incibe.es",
"affectedData": [
{
"vendor": "Ghost Robotics",
"product": "Vision 60",
"versions": [
{
"status": "affected",
"version": "0.27.2"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-10-22T09:15:36.423",
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-ghost-robotics-vision-60",
"tags": [
"Third Party Advisory"
],
"source": "cve-coordination@incibe.es"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The communication protocol implemented in Ghost Robotics Vision 60 v0.27.2 could allow an attacker to send commands to the robot from an external attack station, impersonating the control station (tablet) and gaining unauthorised full control of the robot. The absence of encryption and authentication mechanisms in the communication protocol allows an attacker to capture legitimate traffic between the robot and the controller, replicate it, and send any valid command to the robot from any attacking computer or device. The communication protocol used in this interface is based on MAVLink, a widely documented protocol, which increases the likelihood of attack. There are two methods for connecting to the robot remotely: Wi-Fi and 4G/LTE."
}
],
"lastModified": "2026-06-17T09:22:35.867",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ghostrobotics:vision_60_firmware:0.27.2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6C0D9971-6E9B-4F72-B650-A3FD0B004507"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ghostrobotics:vision_60:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5E213EE6-FF18-4C56-8CE0-50E140A650E3"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve-coordination@incibe.es"
}